EVALUATION OF EFFECTIVENESS OF VARIOUS METHODS OF DETERMINING THE NORMAL VALUES OF LUNG MECHANICS PARAMETERS IN THE DIAGNOSTICS OF RESTRICTIVE VENTILATION DISORDERS
- Authors: Kameneva MY1
-
Affiliations:
- First St. Petersburg State Medical University named after I. P. Pavlov
- Issue: Vol 18, No 2 (2014)
- Pages: 24-28
- Section: Articles
- URL: https://journals.eco-vector.com/RFD/article/view/3556
- DOI: https://doi.org/10.17816/RFD2014224-28
- ID: 3556
Cite item
Full Text
Abstract
For early diagnosis of disseminated lung diseases (DLD) is very important to detect a restrictive ventilation disorders in the primary examination of the patient in the offices of general practitioners or outpatient departments. The article discusses the role of spirometry in screening of DLD, compares the effectiveness of existing diagnostic algorithm of restrictive ventilation disorders using predicted values and the low limit of normal. It is shown that the best results are achieved with predicted values, but even in this case, the spirometry parameters of half of the DLD patients remain normal.
About the authors
M Y Kameneva
First St. Petersburg State Medical University named after I. P. Pavlov
References
- Miller M. R., Hankinson J., Brusasco V., Burgos F., Casaburi R., Coates A., Crapo R., Enright P., van der Grinten C. P., Gustafsson P., Jensen R., Johnson D. C., MacIntyre N., McKay R., Navajas D., Pedersen O. F., Pellegrino R., Viegi G., Wanger J. ATS/ERS Task Force. Standardization of spirometry // Eur. Respir. J. - 2005. - Vol. 26. - P. 319-338.
- Miller M. R., Quanjer P. H., Swanney M. P., Ruppel G., Enright P. L. Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients // Chest. - 2011. - Vol. 139. - P. 52-59.
- Hansen J. E. Lower limit of normal is better than 70% or 80% // Chest. - 2011. - Vol. 139. - P. 6-8.
- Каменева М. Ю., Тишков А. В., Быхова А. В., Похазникова М. А., Трофимов В. И. Анализ согласованности некоторых референсных систем при интерпретации результатов спирометрии // Российский семейный врач. - 2012. - Т. 16. - № 2. - С. 23-28.
- Iyer V. N., Schroeder D. R., Parker K. O., Hyatt R. E., Scanlon P. D. The nonspecific pulmonary function test. Longitudinal follow-up and outcomes // Chest. - 2011. - Vol. 139. - № 4. - P. 878-886.
- Каменева М. Ю. Стратегия применения легочных функциональных тестов в работе врача общей практики // Российский семейный врач. - 2012. - Т. 16. - № 2. - С. 4-8.
- European Community for Steel and Coal: standardized lung function testing // Eur. Respir. J. - 1993. - Vol. 6. - № 16, suppl. - P. 5-40.
- Pellegrino R., Viegi G., Brusasco V., Crapo R. O., Burgos F., Casaburi R., Coates A., van der Grinten C. P., Gustafsson P., Hankinson J., Jensen R., Johnson D. C., MacIntyre N., McKay R., Miller M. R., Navajas D., Pedersen O. F., Wanger J. Interpretative strategies for lung function tests // Eur. Respir. J. - 2005. - Vol. 26. - P. 948-968.
- Илькович М. М., Новикова Л. Н., Илькович Ю. М. Диссеминированные заболевания легких в практике семейного врача // Российский семейный врач. - 2012. - Т. 16. - № 2. - С. 16-22.