Modern compressors of the Yaroslavl JSC "Kholodmash" for commercial and industrial refrigeration units
- Authors: Beregovich I.N.
- Issue: Vol 90, No 8 (2001)
- Pages: 2-5
- Section: Articles
- URL: https://freezetech.ru/0023-124X/article/view/104533
- DOI: https://doi.org/10.17816/RF104533
- ID: 104533
Cite item
Full Text
Abstract
Despite the problems associated with the transition to the market, the staff of the Yaroslavl JSC "Kholodmash" concentrated its efforts on the development of production, the improvement of compressor technology and compressor building technology. Today Yaroslavl JSC "Kholodmash" has a wide range of compressors produced not only under license, but also on the basis of its own developments. In a short time, it was possible to put into operation an additional 22,000 m2 of production space, conclude a contract for the manufacture of 600,000 compressors per year under a license from Electrolux Compressors, and build a workshop for this. Compressors produced today comply with European quality and safety requirements and are fully interchangeable in terms of technical characteristics and connecting dimensions with similar models of compressors from ASPERA, UNIDAD HERMETICA, L’UNITE HERMETIQUE, etc.
Modern electrically insulating polyester materials, class 200 enamel wire, mineral and polyester refrigerating oils from the best foreign companies (such as MOBIL, SHELL and FUCHS) provide high quality and reliability of compressors when operating on ozone-friendly refrigerants. Quality control is carried out at all stages of production, from the input control of materials and components to testing on stands and final acceptance of compressors
Keywords
Full Text
В данной статье рассматриваются лицензионные компрессоры серии Р, серийно освоенные АО «Холодмаш». В табл.1 приведены их технические характеристики. Любая модель может быть поставлена потребителю в установленном порядке. Холодопроизводительность, потребляемую мощность и холодильный коэффициент определяли в режимах, представленных в табл. 2.
Практика эксплуатации герметичных компрессоров в России свидетельствует о том, что, несмотря на большой объем их закупок за рубежом, у основной массы потребителей до настоящего времени возникают затруднения в правильном подборе, монтаже, наладке и обслуживании компрессоров.
Условные обозначения лицензионных компрессоров серии Р имеют следующую структуру:
- RG Р 10АВ
- страна-изготовитель компрессора (R - Россия);
- марка хладагента (отсутствие буквы означает, что это хладагент - R22; G - R134a; Н - R600a; М - R404A/R507);
- Серия компрессоров (Р - серия компрессоров с объемом, описанным за 1 оборот, равным 10... 16 см3);
- объем, описанный поршнем за 1 оборот, в кубических сантиметрах (двузначное число);
- область применения (табл. 3);
- характеристики электродвигателя (табл.4).
Габаритные и установочные размеры компрессоров представлены на рис. 1 и в табл.5, а схемы монтажа - на рис. 2. Принципиальные электрические схемы компрессоров показаны на рис. 3 и 4.
Холодильное оборудование, в которое монтируют компрессор, должно отвечать следующим требованиям:
- соответствовать по назначению монтируемому компрессору;
- быть чистым, не содержать во внутренних полостях грязи, стружки, посторонних частиц, масел, красок, окалины, флюсов, окислов и т.п.; допустимое остаточное загрязнение не более 30 мг;
- быть сухим; допустимое остаточное влагосодержание не более 40 мг;
- быть герметичным; допустимая утечка через одну неплотность не более 0,5 г в год;
- гарантировать возврат масла в компрессор (уклоны трубопроводов в сторону компрессора, маслоподъемные петли и т.д.);
- обеспечивать обдув компрессора для моделей с охлаждением вентилятором F (см. табл. 1)].
Помещение для холодильного оборудования должно быть:
- чистым, сухим, хорошо проветриваемым или вентилируемым;
- просторным (объем не менее 20 м3 на каждые 1000 Вт холодопроизводительности устанавливаемого оборудования) или иметь приточно-вытяжную вентиляцию;
- удобным для работы обслуживающего персонала.
Кроме того, помещение должно защищать оборудование от атмосферных осадков и прямой солнечной радиации.
Смонтированную холодильную систему вакуумируют с помощью вакуум-насоса до остаточного давления 1,323 кПа (10 мм рт.ст.) с промежуточным заполнением системы хладагентом или без такого заполнения, но уже достаточного давления не выше 0,0133 кПа (0,1 мм рт.ст.). Давление измеряют мановакуумметром, установленным в холодильной системе, а не на вакуум-насосе.
При пуске компрессоре следует руководствоваться следующими рекомендациями:
- не включать компрессор с перекрытыми всасывающим и нагнетательных трубопроводами;
- не осуществлять незаземленного компрессора;
- не оттаивать испаритель горячими парами хладагента, если на всасывающей линии не установлен отделитель жидкости.
Таблица 1
Характеристики компрессоров серии Р
Модель компрессора | Объем, описанный за 1 оборот, см3 | Масса, кг | Марка хладагента | Смазочное масло | Режим | Диапазон температур, °C | Дроссельный элемент | Тип охлаждения компрессора | Тип двигателя | Пусковой момент | Холодопроизводительность Q потребляемая мощность IV и холодильный коэффициент е в режимах (см. табл. 2) | ||||||||||||
Масса заправки, г | Марка | I(t=-23,3°С; tк=55°С) | II (t0=7,2°С; t=55°С) | III (t0=-35°С; tи=30°С) | IV «t=-15°С; t=30°С) | ||||||||||||||||||
Со- Вт | А'. Вт | е | Вт | N. Вт | Е | С., Вт | N, Вт | Е | Со, Вт | N. Вт | Е | ||||||||||||
RGP10AB | 10 | 11,5 | R134a | 400 | RL22H | LBP | -35...-10 | С | S | RS1R | M | 226 | 195 | 1,16 |
|
|
| 130 | 140 | 0,93 |
|
|
|
RGP10BB | 10 | 11,5 | RI 34а | 400 | RL22H | LBP | -35...-10 | С | ОС | RS1R | M | 226 | 195 | 1,16 |
|
|
| 130 | 140 | 0,93 |
|
|
|
RGP10CB | 10 | 11,5 | R134a | 400 | RL22H | LBP | -35...-10 | С | F | RSIR | м | 226 | 195 | 1,16 |
|
|
| 130 | 140 | 0,93 |
|
|
|
RGP10FB | 10 | 11,5 | RI 34а | 400 | RL22H | LBP | -35...-10 | С или V | F | CSIR | Б | 226 | 195 | 1,16 |
|
|
| 130 | 140 | 0,93 |
|
|
|
RGPI0PB | 10 | 11,0 | RI 34а | 400 | RL22H | НМВР | -25...+10 | С или V | F | RSIR | М |
|
|
| 1005 | 485 | 2,07 |
|
|
| 455 | 250 | 1,82 |
RGPI0TB | 10 | 11,0 | RI 34а | 400 | RL22H | НМВР | -25...+10 | С или V | F | CSIR | Б |
|
|
| 1005 | 485 | 2,07 |
|
|
| 455 | 250 | 1,82 |
RGP12AB | 12 | 11,5 | R134a | 400 | RL22H | LBP | -35...-10 | С | S | RSIR | М | 262 | 230 | 1,14 |
|
|
| 155 | 160 | 0,97 |
|
|
|
RGPI2BB | 12 | 11,5 | RI 34а | 400 | RL22H | LBP | -35...-I0 | С | ОС | RSIR | М | 262 | 230 | 1.14 |
|
|
| 155 | 160 | 0,97 |
|
|
|
RGP12CB | 12 | П,5 | RI 34a | 400 | RL22H | LBP | -35...-10 | с | F | RSIR | м | 262 | 230 | 1Д4 |
|
|
| 155 | 160 | 0,97 |
|
|
|
RGP12EB | 12 | 11,5 | RI 34a | 400 | RL22H | LBP | -35...-1O | С или V | ОС | CSIR | Б | 262 | 230 | U4 |
|
|
| 155 | 160 | 0,97 |
|
|
|
RGP12FR | 12 | 11,5 | RI 34a | 400 | RL22H | LBP | -35...-10 | С или V | г | CSIR | Б | 262 | 230 | 1,14 |
|
|
| 155 | 160 | 0.97 |
|
|
|
RGP12PB | 12 | 11.2 | RI 34a | 350 | RL22H | НМВР | -25...+10 | С или V | F | RSIR | М |
|
|
| 1068 | 518 | 2,06 |
|
|
| 545 | 280 | 1,95 |
RGP12TB | 12 | 11,2 | RI 34a | 350 | RL22H | НМВР | -25...+1O | С или V | F | CSIR | Б |
|
|
| 1068 | 518 | 2,06 |
|
|
| 545 | 280 | 1,95 |
RGP14BB | 14 | 11.5 | RI 34a | 470 | RL22H | LBP | -35...-10 | С | ОС | RSIR | М | 315 | 270 | 1,16 |
|
|
| 185 | 185 | 1 |
|
|
|
RGP14CB | 14 | 11.5 | RI 34a | 470 | RL22H | LBP | -35...-10 | С | F | RSIR | М | 315 | 270 | 1,16 |
|
|
| 185 | 185 | 1 |
|
|
|
RGP14EB | 14 | 11,5 | RI 34a | 400 | RL22H | LBP | -35...-I0 | С или V | ОС | CSIR | Б | 315 | 270 | 1,16 |
|
|
| 185 | 185 | 1 |
|
|
|
RGP14FB | 14 | 11,5 | RI34a | 470 | RL22H | LBP | -35...-10 | С | F | CSIR | Б | 315 | 270 | 1,16 |
|
|
| 185 | 185 | 1 |
|
|
|
RGP14PB | 14 | 11,5 | RI 34a | 400 | RL22H | HMBP | -25...+ 10 | С или V | F | RSIR | М |
|
|
| 1195 | 588 | 2,03 |
|
|
| 630 | 320 | 1.97 |
RGP14TB | 14 | 11,5 | RI 34a | 400 | RL22H | HMBP | -25...+10 | С или V | F | CSIR | Б |
|
|
| 1195 | 588 | 2.03 |
|
|
| 630 | 320 | 1.97 |
RGP16BB | 16,14 | 12 | RI 34a | 530 | RL22H | LBP | -35...-10 | С | ОС | RSIR | М | 366 | 321 | 1.14 |
|
|
| 220 | 230 | 0,96 |
|
|
|
RGPI6CB | 16.14 | 12 | RI 34a | 530 | RL22H | LBP | -35...-10 | С | F | RSIR | М | 366 | 321 | 1,14 |
|
|
| 220 | 230 | 0,96 |
|
|
|
RGP16EB | 16.14 | 12 | R134a | 530 | RL22H | LBP | -35...-10 | С или V | ОС | CSIR | Б | 366 | 321 | 1,14 |
|
|
| 220 | 230 | 0,96 |
|
|
|
RGP16FB | 16 | 12 | R134a | 530 | RL22H | LBP | -35...-10 | С или V | г | CSIR | Б | 366 | 321 | 1.14 |
|
|
| 220 | 230 | 0,96 |
|
|
|
RGP16TB | 16 | 13,1 | RI 34a | 320 | RL22H | HMBP | -15...+ 10 | С или V | г | CSIR | Б |
|
|
| 1439 | 688 | 2Д)9 |
|
|
| 740 | 380 | 1,95 |
RP1QTN | 10 | 11,5 | R22 | 400 | G68 | HMBP | -25...-10 | С или V | F | CSR | Б |
|
|
| 1360 | 735 | 1,85 |
|
|
| 600 | 320 | 1,88 |
RP12TN | 12 | 12,3 | R22 | 400 | G68 | HMBP | -25...+10 | С или V | F | CSR | Б |
|
|
| 1535 | 679 | 2,26 |
|
|
| 875 | 380 | 2.3 |
RPI3UM | 13,4 | 12,3 | R22 | 400 | НТ25 | AC | - 10... + 10 | С | F | CSR | Б |
|
|
| 1735 | 738 | 2,35. |
|
|
|
|
|
|
RHPI0AA | 9.93 | 10 | R600a | 400 | 4322 | LBP | -30...-10 | С | S | RSIR | М | 137 | 112 | 1,23 |
|
|
|
|
|
|
|
|
|
RHP12AA | 12,1 | 10,4 | R600a | 400 | 4322 | LBP | -30...-10 | с | S | RSIR | М | 174 | 149 | 1,17 |
|
|
|
|
|
|
|
|
|
RHP14AA | 14,31 | 10,7 | R600a | 400 | 4322 | LBP | -30...-10 | с | S | RSIR | М | 200 | 169 | 1,18 |
|
|
|
|
|
|
|
|
|
RHP16AA | 16,14 | 10,9 | R600a | 400 | 4322 | LBP | -30...-10 | с | S | RSIR | М | 222 | 186 | 1,19 |
|
|
|
|
|
|
|
|
|
RMP10FB | 10 | 12 | R404a | 400 | RL46S | LBP | -40...-10 | С или V | F | CSIR | Б | 465 | 465 | 1 |
|
|
| 300 | 300 | 1 |
|
|
|
RMP10TB | 10 | 12 | R404a | 400 | RL46S | HMBP | -25...+10 | С или V | F | CSIR | Б |
|
|
| 1569 | 747 | 2,1 |
|
|
| 950 | 440 | 2,16 |
RMP12FB | 12 | 12 | R404a | 400 | RL46S | LBP | -40...-10 | С или V | F | CSIR | Б | 522 | 450 | 1,16 |
|
|
| 350 | 320 | 1,1 |
|
|
|
RMPI2TB | 12 | 13,5 | R404a | 400 | RL46S | HMBP | -25...+10 | С или V | F | CSIR | Б |
|
|
| 1833 | 797 | 2.3 |
|
|
| 1120 | 460 | 2,43 |
RMP14FB | 14 | 13,9 | R404a | 400 | RL46S | LBP | -40...-10 | С или V | F | CSIR | Б | 627 | 560 | 1,12 |
|
|
| 400 | 420 | 0.95 |
|
|
|
RMP14TB | 14 | 13,5 | R404a | 400 | RL46S | HMBP | -25...+1 | С или V | F | CSR | Б |
|
|
| 2090 | 977 | 2.14 |
|
|
| 1260 | 565 | 2,23 |
Примечания: I. В табл. I приняты следующие обозначения: НМВР - среднетемпературная холодильная техника; LBP - низкотемпературная холодильная техника; АС - кондиционирование воздуха; С - капиллярная трубка; V - вентиль терморегулируюший; S, ОС, F - охлаждение компрессора (S - при естественной конвекции, ОС - маслом, дополнительно охлаждаемым в маслоохладителе. F - вохтушное с помощью вентилятора); RSIR - подключение пусковой обмотки при пуске (используется токовое пусковое реле или позистор); CSIR - подключение пусковой обмотки с пусковым конденсатором при пуске (используется токовое пусковое реле); CSR - подключение рабочего конденсатора к пусковой обмотке постоянно и пускового конденсатора при пуске (используется реле напряжения); М - малый пусковой момент; Б - большой пусковой момент.
Род тока - однофазный (напряжение 220...240 В, частота 50 Гц); пуск обеспечивается при минимальном напряжении 187 В.
Корректированный уровень звуковой мощности 39..63 дБА в зависимости от модели.
Максимальная температура окружающей среды 43 °C.
Рис. 1. Габаритные и установочные размеры компрессоров (см. табл. 5) * Размеры для компрессоров RP10TN, RP12TN, RP13 UM, RMP12TR, RMP14TB. ** Размеры для компрессоров с маслоохладителем (ОС)
Таблица 2
Температура, °C | Режимы | |||
1 | II | III | IV | |
LBP | НМВР | ГОСТ | ||
Низкотемпературный | Средне- температурный | |||
Кипения | -23,3 | 7,2 | -35 | -15 |
Конденсации | 55 | 55 | 30 | 30 |
Жидкости перед терморегулирующим вентилем | 55 | 55 | - | - |
Пара на всасывании | 32 | 35 | 20 | 20 |
Окружающей среды | 32 | 35 | 20 | 20 |
Таблица 3
Обозначение |
Область применения | Пусковой момент | Тип охлаждения* |
A | Низкотемпературная холодильная техника (LBP) | Малый (М) | S |
B | ОС | ||
C | F | ||
Е | Большой (Б) | ОС | |
F | F | ||
Р | Среднетемпературная холодильная техника (НМВР) | Малый (М) | |
Т | Большой (Б) | ||
U | Высокотемпературная техника (кондиционирование) |
* Обозначения типа охлаждения см. примечание к табл. 1.
Рис. 2. Схема Монтажа компрессора: а — под размер в лапах компрессора /65±0,5x101,6+0,5 мм; б — под размер в лапах компрессора 170±0,5x70+0,5 мм; 1 — амортизационная втулка; 2 — лапа компрессора; 3 - амортизатор; 4 - основание агрегата; 5 – шайба
Таблица 4
Обозначение | Эффективность | Схема пуска* |
А | Средняя | RSIR |
В | Стандартная | PS1R/CSIR |
М N | Стандартная | CSR
|
* Обозначения схемы пуска см. табл. 1.
Рис. 3. Принципиальная электрическая схема компрессоров с двигателями RSIR, CSJR.- M I - электродвигатель компрессора (220...240 В; 50 Гц); XT — узел заземления; Р — вывод рабочей обмотки; А — вывод пусковой обмотки; С — общий вывод; A I — защитное реле; Л2 — пусковое реле; X I — клеммный блок; Сп — пусковой конденсатор. Примечания: I. Соединения, показанные пунктирной линией, термостат В заводом не поставляются и монтируются потребителем. 2. * только для компрессоров с пусковым конденсатором (двигатель CSJR)
Таблица 5
Модель компрессора | Размер | ||||
A | D | H | B | C | |
RGPIOAB/CB/FB, RGPI2AB/CB/FB, RP12CV |
203 |
133 |
4,9 |
8,1 | 8,1 |
RGP10PB/TB, RGP12PB/TB. RGPI4BB/CB/EB/FB | 6,55 | 8,1 | 8,1 | ||
RHP16AA |
| 6,1 | 6,1 | ||
RHPIOAA. RHP12AA. RHPI4AA | 4,9 | 6.1 | 6,1 | ||
RGPI2BB/FB, RP12BV | 216 | 146 | 4,9 | 8,1 | 8,1 |
RP10TN, RP12TN, RPI3UM.RMP12TB. RMP14TB | 6,55 | 9,7 | 8,1 | ||
RGPIOBB. RGPI4PB/TB, RGPI6BB/CB/LB/FB/TB, DMP1ACR/TRO PMPUFR RPI4TY | 6,55 | 8,1 | 8,1 |
Примечание. Предельное отклонение размеров Н. В и С не более +0,1.
Рис. 4. Принципиальная электрическая схема компрессоров с двигателем CSR: M l — электродвигатель компрессора (220...240 В; 50 Гц); М2 - вентилятор (в комплект компрессора не входит); Р— вывод рабочей обмотки; А — вывод пусковой обмотки; С — общий вывод; А1 — защитное реле; А2 — пусковое реле; Сп — пусковой конденсатор: Ср — рабочий конденсатор. Примечание. Соединения, показанные пунктирной линией, вентилятор М2, термостат В заводом не поставляются и монтируются потребителем
При максимально допустимой температуре окружающей среды 43 °C и максимальном напряжении в сети температура обмотки электродвигателя не должна превышать 130 °C;
Максимальная температура нагнетания, измеренная изолированной термопарой на нагнетательном патрубке на расстоянии 5 см от кожуха компрессора при непрерывной работе в условиях охлаждения при естественной конвекции, не должна превышать 120 °C; для воздушного охлаждения с помощью вентилятора 105 °C; при экстремальных условиях - соответственно 135 и 125 °C.
Температура всасывания должна быть такой, чтобы исключить попадание жидкого хладагента в компрессор.
Коэффициент рабочего времени не должен быть более 0,8; допускается в случае загрузки холодильного оборудования работа в течение ограниченного времени с коэффициентом, равным 1.
Допустимая максимальная частота включений (ч 1) составляет для компрессоров:
Без пускового конденсатора, не более 5
С пусковым конденсатором при стабильной работе, не более 12
при работе в ограниченный период времени 20
Компрессоры предназначены для комплектации различного холодильного оборудования, в том числе для коммерческого (камеры, прилавки, витрины, шкафы, низкотемпературные лари), бытового (холодильники, морозильники, низкотемпературные лари) и установок кондиционирования воздуха (кондиционеры холодопроизводительностью до Qo = 2 кВт). Они могут быть использованы в том числе и на холодильном транспорте.
Таблица 6
Объем морозильной камеры, л | Тип компрессора (R134а, t0=-30°С) | |||
150 | - | RHP10AA | - | - |
200 | - | RHP12AA | - | - |
250 | - | RHP14AA | - | RMP10 FB |
300 | RGP10BB | ЗВВ RHP16AA | - | RMP12 FB |
350 | RG Р12BB | - | - | RMP14 FB |
400 | RGP14 BB | - | - | - |
500 | - | RMP10 FB | - | - |
600 | - | RMP12 FB
| - | - |
700 | - | - | RMP14 FB | - |
В качестве примера можно привести следующие ориентировочные рекомендации для применение компрессоров фирмы «Electrolux Compres-sors»B морозильных камерах при температуре окружающего воздуха не выше 43 °C (табл. 6).
Сведения, приведенные в табл. 6, имеют рекомендательный характер. В зависимости от условий и качества холодильной установки можно вносить корректировки.
Рис. 5. Область применения компрессоров. Температура окружающей среды 4.3 ° С, температура пара на всасывании 25 и С. Обозначения режимов см. в примечании к табл. 1. Область применения компрессоров RGP и RHP серии Р для режима LBP указана в табл. 1, для остальных приведена на рис. 5.
Лицензионные компрессоры производства Ярославского АО «Холодмаш» имеют ряд преимуществ перед импортными аналогами. Они адаптированы к российским условиям, сохраняют работоспособность при падении напряжения до 180 В, выдерживают вибрационные и ударные нагрузки при транспортировке. В конструкции компрессоров применен обмоточный провод с 12-слойным покрытием эмалью, выдерживающей температуру 210 °C. Всегда выполняются гарантийные обязательства.
About the authors
I. N. Beregovich
Author for correspondence.
Email: info@eco-vector.com
Russian Federation