<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">N.N. Priorov Journal of Traumatology and Orthopedics</journal-id><journal-title-group><journal-title xml:lang="en">N.N. Priorov Journal of Traumatology and Orthopedics</journal-title><trans-title-group xml:lang="ru"><trans-title>Вестник травматологии и ортопедии им. Н.Н. Приорова</trans-title></trans-title-group></journal-title-group><issn publication-format="print">0869-8678</issn><issn publication-format="electronic">2658-6738</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">104421</article-id><article-id pub-id-type="doi">10.17816/vto104421</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Original study articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Оригинальные исследования</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Total hip arthroplasty with own design endoprosthesis</article-title><trans-title-group xml:lang="ru"><trans-title>Тотальное эндопротезирование тазобедренного сустава эндопротезом собственной конструкции</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Rutsky</surname><given-names>A. V.</given-names></name><name xml:lang="ru"><surname>Руцкий</surname><given-names>А. В.</given-names></name></name-alternatives><address><country country="BY">Belarus</country></address><email>info@eco-vector.com</email><xref ref-type="aff" rid="aff1"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Belarusian State Institute for Postgraduate Medical Education</institution></aff><aff><institution xml:lang="ru">Белорусский государственный институт усовершенствования врачей</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2000-12-17" publication-format="electronic"><day>17</day><month>12</month><year>2000</year></pub-date><volume>7</volume><issue>4</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>34</fpage><lpage>38</lpage><history><date date-type="received" iso-8601-date="2022-03-03"><day>03</day><month>03</month><year>2022</year></date><date date-type="accepted" iso-8601-date="2022-03-03"><day>03</day><month>03</month><year>2022</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2022, Eco-Vector</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2022, ООО "Эко-Вектор"</copyright-statement><copyright-year>2022</copyright-year><copyright-holder xml:lang="en">Eco-Vector</copyright-holder><copyright-holder xml:lang="ru">ООО "Эко-Вектор"</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/></permissions><self-uri xlink:href="https://journals.eco-vector.com/0869-8678/article/view/104421">https://journals.eco-vector.com/0869-8678/article/view/104421</self-uri><abstract xml:lang="en"><p><italic>The</italic><italic> basis of hip joint implant elaboration is the principle of primary stable fixation of its components. This is achieved owing to the peculiarities of the implants design, its shape, proportions, surface structure. The stem of the implant is wedge-shaped in three dimensions («triwedge»). The cup has a shape of truncated cone with a spherical segment as an apex. In the proximal stem and spherical segment of the polymeric cup there are porous inserts with pores of 150-350 mkm. This provides the bone ingrowth into implant without disturbance of its nutrition as proved out by the experimental data. The implant is made of high-quality materials by modern production process. Since 1999 more than 600 operations using new implant were performed in Belarus. 173 patients were operated on at the Trauma and Orthopaedic Clinic of the Belarus Institute for Advanced Medical Studies during 1997-1999. </italic><italic>Preliminary</italic><italic> results are favorable.</italic></p></abstract><trans-abstract xml:lang="ru"><p><italic>В основу разработки эндопротеза тазобедренного сустава положен принцип первичностабильной фиксации его компонентов, которая обеспечивается особенностями конструкции имплантата, его формой, пропорциями, структурой поверхности. Ножка протеза имеет клинообразную форму в трех плоскостях («триклин»). Чашка выполнена в виде усеченного конуса, вершина которого — сферический сегмент. В проксимальной части ножки и сферическом сегменте полимерного вкладыша чашки имеются пористые вставки с размером пор от 150 до 350 мкм. Это обеспечивает врастание кости в имплантат без нарушения ее питания, что подтверждено экспериментальными исследованиями. Эндопротез изготавливается по современным технологиям из высококачественных материалов. За период с 1996 г. в специализированных отделениях областных больниц Республики Беларусь имплантировано более 600 таких эндопротезов. В клинике травматологии и ортопедии Белорусского института усовершенствования врачей в 1997-1999 г. эндопротезирование произведено 173 больным. Предварительные</italic> <italic>результаты</italic> <italic>лечения</italic> <italic>благоприятные</italic><italic>.</italic></p></trans-abstract><kwd-group xml:lang="en"><kwd>endoprosthesis</kwd><kwd>hip joint</kwd><kwd>endoprosthesis</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>эндопротезирование</kwd><kwd>тазобедренный сустав</kwd><kwd>эндопротез</kwd></kwd-group><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Демьянов В.М., Машков В.М. //Актуальные вопросы ортопедии. — Л.,1987. — С. 13-19.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Жаденов И.И., Ковалева И.Д. //Ортопед. травматол.- 1991. — N 8. — С. 71-77.</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Корнилов Н.В. //Травматол. ортопед. России. — 1994. — N 5. — С. 7-11.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Кузьменко В.В., Фокин В.А. //Ортопед. травматол. - 1991.— N 10. — С. 74-78.</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Неверов В.А., Закари С.М. Ревизионное эндопротезирование тазобедренного сустава. — СПб,1977.</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Bensmann G. //Tech. Mitt. Krupp. — 1992. — N 1. — S. 45-69.</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Biolox-forte. Technical information. — Cerasiv GmbH, Plochingen,1996.</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>Semlitsch M. //10 Jahre Zweymueller- Hueftendoprothese. — Huber, Bern etc.,1990. — S. 14-22.</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>Streicher R.M. //Techn. Rundschan Sulzer. — 1991. — N 1. — S. 13-17.</mixed-citation></ref></ref-list></back></article>
