<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="brief-report" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">N.N. Priorov Journal of Traumatology and Orthopedics</journal-id><journal-title-group><journal-title xml:lang="en">N.N. Priorov Journal of Traumatology and Orthopedics</journal-title><trans-title-group xml:lang="ru"><trans-title>Вестник травматологии и ортопедии им. Н.Н. Приорова</trans-title></trans-title-group></journal-title-group><issn publication-format="print">0869-8678</issn><issn publication-format="electronic">2658-6738</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">47630</article-id><article-id pub-id-type="doi">10.17816/vto20140475-78</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Статьи</subject></subj-group><subj-group subj-group-type="article-type"><subject>Short Communication</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Clinical Study of the Influence of Implants Made of Different Metals on the Physical Status of Experimental Animals</article-title><trans-title-group xml:lang="ru"><trans-title>Clinical Study of the Influence of Implants Made of Different Metals on the Physical Status of Experimental Animals</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Gatina</surname><given-names>E. B</given-names></name><name xml:lang="ru"><surname>Гатина</surname><given-names>Э. Б</given-names></name></name-alternatives><bio xml:lang="ru"><p>канд. мед. наук, соискатель кафедры травматологии, ортопедии и хирургии экстремальных состояний КГМУ</p></bio><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Akhtyamov</surname><given-names>I. F</given-names></name><name xml:lang="ru"><surname>Ахтямов</surname><given-names>Ильдар Фуатович</given-names></name></name-alternatives><bio xml:lang="ru"><p>доктор мед. наук, проф., зав. кафедрой травматологии, ортопедии и хирургии экстремальных состояний КГМУ, главный науч. сотр. ГАУЗ «РКБ МЗ РТ»; Тел.: +7 (905) 315-01-50.</p></bio><email>yalta60@mail.ru</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Shakirova</surname><given-names>F. V</given-names></name><name xml:lang="ru"><surname>Шакирова</surname><given-names>Ф. В</given-names></name></name-alternatives><bio xml:lang="ru"><p>доктор ветеринарных наук, доцент, зав. кафедрой ветеринарной хирургии КГАВМ</p></bio><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Manirambona</surname><given-names>Zh. K</given-names></name><name xml:lang="ru"><surname>Манирамбона</surname><given-names>Ж. К</given-names></name></name-alternatives><bio xml:lang="ru"><p>аспирант кафедры ветеринарной хирургии КГАВМ</p></bio><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Kazan’ State Medical University, Bauman Kazan’ Russia</institution></aff><aff><institution xml:lang="ru">ГБОУ ВПО «Казанский государственный медицинский университет» Минздрава России</institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en">Bauman Kazan’ State Academy of Veterinary Medicine, Kazan’, Russia</institution></aff><aff><institution xml:lang="ru">ФГБОУ «Казанская государственная академия ветеринарной медицины», Казань, РФ</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2014-12-15" publication-format="electronic"><day>15</day><month>12</month><year>2014</year></pub-date><volume>21</volume><issue>4</issue><issue-title xml:lang="en">NO4 (2014)</issue-title><issue-title xml:lang="ru">№4 (2014)</issue-title><fpage>75</fpage><lpage>78</lpage><history><date date-type="received" iso-8601-date="2020-10-20"><day>20</day><month>10</month><year>2020</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2014, Eco-Vector</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2014, ООО "Эко-Вектор"</copyright-statement><copyright-year>2014</copyright-year><copyright-holder xml:lang="en">Eco-Vector</copyright-holder><copyright-holder xml:lang="ru">ООО "Эко-Вектор"</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/></permissions><self-uri xlink:href="https://journals.eco-vector.com/0869-8678/article/view/47630">https://journals.eco-vector.com/0869-8678/article/view/47630</self-uri><abstract xml:lang="en"><p>Biocompatibility of implants made of steel 12X18H9T, steel 12X18H9T coated with titanium and hafnium nitrides, and steel 12X18H9T coated with titanium and zirconium nitrides was studied in rats. Implants that represented pins 8-10 mm long and 0.5 mm in diameter were inserted intramedullary into the middle third of the tibia after drilling. The ends of pins were turned down and placed under the skin. The wound was sutured tightly. Dynamics of body weight and temperature as well as the condition of the hair, eyes, oral and nasal mucosa were assessed on days 10, 30, 60 and 90 after implantation. It was shown that implants coated with titanium and hafnium nitrides caused minimum systemic and local reactions while implantation of pins coated with titanium and zirconium nitrides resulted in the development of more pronounced inflammatory changes on both the local and systemic level.</p></abstract><trans-abstract xml:lang="ru"><p>Проведено исследование на крысах по изучению биологической совместимости имплантатов из стали 12X18H9T, стали 12X18H9T с покрытием нитридами титана и гафния, а также стали 12X18H9T с покрытием нитридами титана и циркония. Имплантаты, которые представляли собой шпильки длиной 8-10 мм и диаметром 0,5 мм, вводили интрамедулярно в среднюю треть диафиза большой берцовой кости чрескостно после предварительного рассверливания. Концы шпилек загибали в виде скобы и погружали под кожу. Рану ушивали наглухо. Оценивали динамику массы и температуры тела на 10, 30, 60 и 90-е сутки после имплантации, а также состояния волосяного покрова, глаз, слизистых носа и ротовой полости. Установлено, что нахождение имплантатов с покрытием из смеси нитридов титана и гафния сопровождалось минимальными общими и локальными реакциями, тогда как имплантация шпилек с покрытием из нитридов титана и циркония обусловила развитие выраженных воспалительных изменений на местном и системном уровне.</p></trans-abstract><kwd-group xml:lang="en"><kwd>implant</kwd><kwd>coatings</kwd><kwd>titanium and zirconium nitrides</kwd><kwd>titanium and hafnium nitrides</kwd><kwd>conjunctivitis</kwd><kwd>ulcerative orchitis</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>имплантат</kwd><kwd>покрытия</kwd><kwd>нитрид титана и циркония</kwd><kwd>нитрид титана гафния</kwd></kwd-group></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Абдуллин И.Ш., Миронов М.М., Гарипова Г.И. Бактерицидные и биологически стойкие покрытия для медицинских имплантатов и инструментов. Медицинская техника. 2004; 4: 20-2.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Steinemann S.G. Metal implants and surface reactions. Injury. 1996; 27: Supp l3: SC 16-22.</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Summer B., Fink U., Zeller R., Rueff F., Maier S., Roider G., Thomas P. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release. Contact Dermatitis. 2007; 57 (1): 35-9.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Thomas P., Summer B., Krenn V., Thomsen M. Allergy diagnostics in suspected metal implant intolerance. Orthopade. 2013; 42 (8): 602-6 [article in German].</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Загородний Н.В., Бухтин К.М., Кудинов О.А., Чрагян Г.А., Берченко Г.Н., Николаев И.А. Реакция на кобальт как причина ревизионного эндопротезирования коленного сустава. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2013; 2: 65-8.</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Horowitz S.M., Purdon M.A. Mechanisms of cellular recruitment inaseptic loosening of prosthetic joint implants. Calcif. Tissue Int. 1995; 57: 301-5.</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Sovak G., Weiss A., Gotman I. Osseointegration of Ti6Al4V alloy implants coated with titanium nitride by a new method. J. Bone Joint Surg. Br. 2000; 82 (2): 290-6.</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>Amstutz H.C., Campbell P., Kossovsky N., Clarke I.C. Mechanism andclinical significance of wear debris inducedosteolysis. Clin. Orthop. Relat. Res. 1992; 276: 7-18.</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>Ахтямов И.Ф., Гатина Э.Б., Кадыров Ф.Ф., Шаехов М.Ф., Шакирова Ф.В. Исследование взаимодействия биосовместимого покрытия из смеси нитридов металлов IV группы с тканями живого организма. Вестник Казанского технологического университета. 2012; 15 (20): 176-9.</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>Ахтямов И.Ф., Шакирова Ф.В., Гатина Э.Б., Зубаирова Л.Д., Алиев Э.И. Сравнительное изучение ряда сывороточных маркеров при экспериментальном остеосинтезе имплантатами с покрытием нитридами титана и гафния. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2013; 2: 60-4.</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>Ахтямов И.Ф., Шакирова Ф.В., Гатина Э.Б., Зубаирова Л.Д., Алиев Э.И. Оценка острой фазы при экспериментальном остеосинтезе имплантами с биоинертным покрытием нитридами сверхтвердых металлов. Гений ортопедии. 2013; 4: 80-3.</mixed-citation></ref></ref-list></back></article>
