Primary Hip Replacement with Cementless «ESI» Implants

Abstract

Comparative analysis of the outcomes of cementless implantation of total metal-polymeric structurized hip implants «ESI» of various generations was performed. Results of 1095 implantations (876 patients) performed during the period from 1995 to 2008 were evaluated. Follow-up was from 6 months to 12 years (mean term 7.3 years). Comparison of the results was performed between four groups differed by the modification of applied «ESI» implant. Characteristics for every of four «ESI» implant generations were presented. In the first group (1st generation of implants) assessment of treatment outcomes by Harris showed no excellent and good results, satisfactory results made up 4%, poor results - 96%. In the second group (2nd generation) excellent results were achieved in 3% of cases, good one in 18%, satisfactory - in 36% and poor result was noted in 43% of cases. In the third group (3rd generation) the results made up 27, 63, 8 and 2%, respectively. In group four (4th generation) excellent results made up 32%, good - 64%, satisfactory - 4% with no poor results observed.

References

  1. Каграманов С.В., Нуждин В.И. Среднесрочные результаты применения отечественного имплантата ЭСИ в практике первичного тотального эндопротезирования тазобедренного сустава //Вестн. травматол. ортопед. -2004. - N 3. - С. 45-49.
  2. Калита В.И., Каграманов С.В., Шатерников Б.Н., Парамонов В.А. //Науч.-практ. конф. SICOT, 13-я. - СПб, 2002. - С. 57-58.
  3. Кудинов О.А. Клинико-рентгенологические и патоморфологические сопоставления при дегенеративно-дистрофических заболеваниях тазобедренного сустава в клинике эндопротезирования: Автореф. дис. ... канд. мед. наук. - М., 2000.
  4. Надеев А.А., Надеев А.А., Иванников С.В., Шестерня Н.А. Рациональное эндопротезирование тазобедренного сустава. - М., 2004. - С. 188-191.
  5. Collier J.P., Surprenant V.A., Jengen R.E. et al. Corrosion between the components of modular femoral hip prostheses //J. Bone Jt Surg. - 1992. - Vol. 74. - P. 511.
  6. Davidson D., Pike J., Garbuz D. et al. Intraoperative periprosthetic fracture during total hip arthroplasty //J. Bone Jt Surg. - 2008. - Vol. 90A. - Р. 2000-2012.
  7. Engh C.A., Bobyn J.D., Glassman A.H. Porous-coated hip replacement: The factors governing bone ingrowth, stress shielding, and clinical results //J. Bone Jt Surg. - 1987. - Vol. 69B. - Р. 45-55.
  8. Ferguson A.B., Lainy P.G., Hodge E.S. The ionization of metals implants in living tissues //J. Bone Jt Surg. - 1960. - Vol. 42A. - Р. 77-90.
  9. Harris W.H. Traumatic arthritis of hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end result study using a new method of result evaluation //J. Bone Jt Surg. - 1969. - Vol. 51A. - P. 737-755.
  10. Lombardi A.V., Mallori T.N., Vanghn B.K., Dronillard P. Aseptic loosening in total hip arthroplasty secondary to osteolysis in duced by wear debris from titanium alloy modular femoral heads //J. Bone Jt Surg. - 1989. - Vol. 71A. - Р. 1337.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2009 Eco-Vector



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77-76249 от 19.07.2019.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies