Biocompatibility of implants made of steel 12X18H9T, steel 12X18H9T coated with titanium and hafnium nitrides, and steel 12X18H9T coated with titanium and zirconium nitrides was studied in rats. Implants that represented pins 8-10 mm long and 0.5 mm in diameter were inserted intramedullary into the middle third of the tibia after drilling. The ends of pins were turned down and placed under the skin. The wound was sutured tightly. Dynamics of body weight and temperature as well as the condition of the hair, eyes, oral and nasal mucosa were assessed on days 10, 30, 60 and 90 after implantation. It was shown that implants coated with titanium and hafnium nitrides caused minimum systemic and local reactions while implantation of pins coated with titanium and zirconium nitrides resulted in the development of more pronounced inflammatory changes on both the local and systemic level.
作者简介
E. Gatina
Kazan’ State Medical University, Bauman Kazan’ Russia
I. Akhtyamov
Kazan’ State Medical University, Bauman Kazan’ Russia
Email: yalta60@mail.ru
F. Shakirova
Bauman Kazan’ State Academy of Veterinary Medicine, Kazan’, Russia
Zh. Manirambona
Bauman Kazan’ State Academy of Veterinary Medicine, Kazan’, Russia
参考
- Абдуллин И.Ш., Миронов М.М., Гарипова Г.И. Бактерицидные и биологически стойкие покрытия для медицинских имплантатов и инструментов. Медицинская техника. 2004; 4: 20-2.
- Steinemann S.G. Metal implants and surface reactions. Injury. 1996; 27: Supp l3: SC 16-22.
- Summer B., Fink U., Zeller R., Rueff F., Maier S., Roider G., Thomas P. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release. Contact Dermatitis. 2007; 57 (1): 35-9.
- Thomas P., Summer B., Krenn V., Thomsen M. Allergy diagnostics in suspected metal implant intolerance. Orthopade. 2013; 42 (8): 602-6 [article in German].
- Загородний Н.В., Бухтин К.М., Кудинов О.А., Чрагян Г.А., Берченко Г.Н., Николаев И.А. Реакция на кобальт как причина ревизионного эндопротезирования коленного сустава. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2013; 2: 65-8.
- Horowitz S.M., Purdon M.A. Mechanisms of cellular recruitment inaseptic loosening of prosthetic joint implants. Calcif. Tissue Int. 1995; 57: 301-5.
- Sovak G., Weiss A., Gotman I. Osseointegration of Ti6Al4V alloy implants coated with titanium nitride by a new method. J. Bone Joint Surg. Br. 2000; 82 (2): 290-6.
- Amstutz H.C., Campbell P., Kossovsky N., Clarke I.C. Mechanism andclinical significance of wear debris inducedosteolysis. Clin. Orthop. Relat. Res. 1992; 276: 7-18.
- Ахтямов И.Ф., Гатина Э.Б., Кадыров Ф.Ф., Шаехов М.Ф., Шакирова Ф.В. Исследование взаимодействия биосовместимого покрытия из смеси нитридов металлов IV группы с тканями живого организма. Вестник Казанского технологического университета. 2012; 15 (20): 176-9.
- Ахтямов И.Ф., Шакирова Ф.В., Гатина Э.Б., Зубаирова Л.Д., Алиев Э.И. Сравнительное изучение ряда сывороточных маркеров при экспериментальном остеосинтезе имплантатами с покрытием нитридами титана и гафния. Вестник травматологии и ортопедии им. Н.Н. Приорова. 2013; 2: 60-4.
- Ахтямов И.Ф., Шакирова Ф.В., Гатина Э.Б., Зубаирова Л.Д., Алиев Э.И. Оценка острой фазы при экспериментальном остеосинтезе имплантами с биоинертным покрытием нитридами сверхтвердых металлов. Гений ортопедии. 2013; 4: 80-3.
补充文件
![](/img/style/loading.gif)