Unscrewed and broken central crews: prevention and troubleshooting
- Authors: Voronin V.F.1, Solodkiy V.G.1, Solodkaya D.V.1, Muraev A.A.1
-
Affiliations:
- Issue: Vol 17, No 3 (2013)
- Pages: 22-26
- Section: Articles
- Submitted: 21.07.2020
- Published: 15.06.2013
- URL: https://rjdentistry.com/1728-2802/article/view/39133
- DOI: https://doi.org/10.17816/dent.39133
- ID: 39133
Cite item
Full Text
Abstract
This article discusses methods and techniques for correction of complications caused by loose, unscrewed or fractured central screws in different implant systems. For this the researchers at the department of maxilla&facial and Implant Surgery of Nizhny Novgorod State Medical Academy and 8 dental practices in Moscow and Nizhny Novgorod it was conducted the examination and treatment of 81 patients with overall 168 cases of loose or fractured central screws with different levels of severity. This article defines causes of such complications. Practicing dentists are given guidelines to detect and prevent the screws from breaking , unscrewing or becoming loose.
Full Text
Профилактика и устранение осложнений, связанных с выкручиванием и переломами центральных винтов в имплантатах×
About the authors
Viktor Fedorovich Voronin
Vladimir Grigoryevich Solodkiy
Dina Vladimirovna Solodkaya
Email: dinkasolodkaia@gmail.com
Alexandr Alexandrovich Muraev
References
- Van den Broeke S.M., de Baat C. Fracture of implant abutment screws and removal of a remaining screw piece. [Article in Dutch]. Ned. Tijdschr. Tandheelkd. 2008; 115 (7): 360-7.
- Солодкий В.Г., Иванов С.Ю., Мураев А.А., Солодкая Д.В., Ларионов Е.В. Патент на полезную модель № 88949 «Устройство для центрации вращательных инструментов при удалении обломка центрального винта двухэтапного стоматологического имплантата» 2009 г.
- Kim B.J., Yeo I.S., Lee J.H., Kim S.K., Heo S.J., Koak J.Y. The effect of screw length on fracture load and abutment strain in dental implants with externalabutment connections. Int. J. Oral Maxillofac. Implants. 2012; 27 (4): 820-3.
- Gupta V., Muley N. A new restorative technique for the perishing implant due to abutment screwfracture. J. Oral Implantol. 2012; Nov. 19.
- Satterthwaite J., Rickman L. Retrieval of a fractured abutment screw thread from an implant: a case report. Br. Dent. J. 2008; 204 (4): 177-80.
- Солодкий В.Г. Разработка супраструктуры для съемных зубных протезов с использованием имплантатов при лечении пациентов с полным отсутствием зубов: Автореф. дис.. канд. мед. наук. М.; 2008.
- Shemtov-Yona K., Rittel D., Levin L., Machtei E.E., Effect of dental implant diameter on fatigue performance. Part I: Mechanical behavior. Clin. Implant. Dent. Relat. Res. 2012; Jul 10.
- Солодкий В.Г. Основные аспекты протезирования с опорой на имплантатах. Клинические примеры. В кн.: Х Всероссийская научно-практическая конференция «Актуальные вопросы стоматологии-2011». Ростов-на-Дону; 23 ноября 2011.
- Shemtov-Yona K., Rittel D., Machtei E.E., Levin L. Effect of dental implant diameter on fatigue performance. Part II: Failure analysis. Clin. Implant. Dent. Relat. Res. 2012; Jul 10.
- Walia M.S., Arora S., Luthra R., Walia P.K. Removal of fractured dental implant screw using a new technique: a case report. J. Oral Implantol. 2012; 38 (6): 747-50.