Impulse оscillometry in the diagnosis of moderate airway obstruction

Cover Page


Cite item

Full Text

Abstract

Background: Impulse oscillometry (IOS) is a non-invasive method for determining respiratory impedance and its parameters. IOS has certain advantages over traditional spirometry.

Aim: To assess the potential of IOS in the diagnosis of moderately severe airway obstruction.

Methods: We examined 53 patients divided in two groups. The first group consisted of 29 patients (26 males and 3 females aged 42 to 89 years) with moderately severe obstructive abnormalities; the second group included 24 patients (17 males and 7 females aged from 18 to 68 years) without ventilatory defects.

Results: Obstructive abnormalities were detected by IOS in 93% of patients in group 1, and the severity of obstruction was more pronounced compared to the results of spirometry in 37% of patients. In group 2, the IOS parameters were normal. There were significant differences in the lung function and IOS parameters between the first and second groups. There were significant correlations between airway resistance and IOS parameters in patients with moderately severe obstructive abnormalities.

Conclusion: Thus impulse oscillometry can be used in the clinical practice to diagnose disorders of respiratory mechanics in patients with moderately severe airway obstruction.

Full Text

ОБОСНОВАНИЕ

Самым простым и распространенным методом исследования функции внешнего дыхания, который можно рассматривать как начальный этап выявления вентиляционных нарушений, прежде всего обструктивных, является спирометрия. Однако при проведении спирометрии требуется выполнение не только спокойных, но и форсированных дыхательных маневров. Следовательно, существует ряд противопоказаний к проведению спирометрии, в частности отсутствие взаимодействия между пациентом и медицинским персоналом.

E. Müller и J. Vogel в 1981 г. наряду с уже существующими методами диагностики нарушений функции бронхолегочной системы предложили использовать импульсную осциллометрию (ИОМ), представляющую собой неинвазивный метод определения дыхательного импеданса (общего дыхательного сопротивления) и составляющих его параметров, прежде всего резистивного компонента дыхательного импеданса (резистивного сопротивления, или резистанса; respiratory resistance, Rrs) при различных частотах осцилляций и реактивного компонента дыхательного импеданса (реактивного сопротивления, или реактанса; respiratory reactance, Хrs). Метод импульсной осциллометрии не требует выполнения форсированных дыхательных маневров, активного участия пациента и его сотрудничества с персоналом, что является большим преимуществом перед спирометрией [1]. Кроме того, ИОМ обладает большей чувствительностью в отношении диагностики обструкции периферических дыхательных путей и широко применяется у больных бронхиальной астмой и хронической обструктивной болезнью легких. Было показано, что анализ параметров Rrs и Хrs помогает проводить дифференциальную диагностику между бронхиальной астмой и хронической обструктивной болезнью легких [2]. Однако остается много неизученных и спорных вопросов, касающихся изменений параметров дыхательного импеданса при вентиляционных нарушениях обструктивного типа разной степени выраженности.

Ранее в наших исследованиях было показано, что базовые параметры ИОМ обладают низкой информативностью при выявлении обструкции дыхательных путей легкой степени: только в 32% случаев были зарегистрированы отклонения от нормы [3]. Кроме того, при использовании классического алгоритма интерпретации показателей ИОМ умеренная обструкция дыхательных путей, диагностированная с помощью спирометрии, была выявлена у 57% пациентов [4]. Таким образом, мы считаем, что вероятность выявления обструктивных нарушений с помощью ИОМ возрастает по мере усугубления обструкции дыхательных путей.

Целью данной работы является изучение возможностей ИОМ в диагностике вентиляционных нарушений обструктивного типа среднетяжелой степени.

МЕТОДЫ

В исследование включены 53 пациента с разнообразной бронхолегочной патологией.

Описание исследования

В работе использованы современные легочные функциональные тесты — спирометрия, бодиплетизмография, ИОМ, которые проводились на установках Master Screen Body, Master Screen PFT PRO и Master Screen IOS (Viasys Healthcare, Германия). Спирометрия и бодиплетизмография выполнены с соблюдением стандартов качества исследований Американского торакального общества (American Thoracic Society, ATS) и Европейского респираторного общества (European Respiratory Society, ERS) [5, 6], а также Российского респираторного общества [7]. Импульсная осциллометрия проводилась на основании рекомендаций H. Smith и соавт. [8].

В результате исследования проведен анализ:

  • спирометрических показателей: форсированной жизненной емкости легких (ФЖЕЛ), объема форсированного выдоха за первую секунду (ОФВ1), ОФВ1/ЖЕЛ (индекс Тиффно) и ОФВ1/ФЖЕЛ, средней объемной скорости на участке кривой поток-объем форсированного выдоха между 25 и 75% ФЖЕЛ (СОС25–75);
  • статических легочных объемов и емкостей: общей емкости легких (ОЕЛ), ЖЕЛ, остаточного объема легких (ООЛ), его доли в общей емкости легких (ООЛ/ОЕЛ), внутригрудного объема газа (ВГО);
  • показателей бронхиального сопротивления: общего бронхиального сопротивления (Rawобщ), бронхиального сопротивления на выдохе (Rawвыд), бронхиального сопротивления на вдохе (Rawвд), бронхиального сопротивления между потоками 0,5 л/с на вдохе и выдохе (Raw5, которое отражает, прежде всего, проходимость центральных дыхательных путей [1]);
  • показателей ИОМ: дыхательного импеданса при частоте осцилляций 5 Гц (Zrs5); резистивного (фрикционного) компонента дыхательного импеданса (резистивного сопротивления) при частоте осцилляций 5 и 20 Гц (Rrs5 и Rrs20 соответственно); реактивного компонента дыхательного импеданса (реактивного сопротивления, или реактанса) при частоте осцилляций 5 Гц (Хrs5), величина которого оценивалась по абсолютной разнице (сдвигу) между его должным и измеренным значением (deltaXrs5=Xrs5долж-Xrs5); частотной зависимости Rrs: относительной, которая рассчитывалась двумя способами: (Rrs5–Rrs20)/Rrs5х100% и (Rrs5–Rrs20)/Rrs20х100%, и абсолютной, которая рассчитывалась как разница Rrs5 и Rrs20, т.е. (Rrs5-Rrs20); резонансной частоты (fres); площади реактанса (АХ); экспираторного ограничения потока (DXrs5); когерентности при частоте осцилляций 5 Гц (Со5) [1].

Cтепень выраженности выявленных изменений показателей функции внешнего дыхания (спирометрии, бодиплетизмографии) оценивалась с учетом требований ATS и ERS [5, 6], а также рекомендаций Российского респираторного общества [7], руководства по клинической физиологии дыхания (под редакцией Л. Шика, Н. Канаева) [9], параметров ИОМ (изменению базовых показателей Rrs5 и Хrs5) [10].

Вентиляционные нарушения обструктивного типа среднетяжелой степени были диагностированы при снижении ОФВ1/ЖЕЛ менее 70% и ОФВ1 в диапазоне 50–60% долж. [11].

Статистический анализ

Статистическая обработка результатов выполнена методами описательной статистики с применением прикладного пакета программ Statistica 10.0. Описательная статистика для числового показателя представлена размером выборки (n), средним значением (М), стандартным отклонением (SD), 95%-ным доверительным интервалом (95% ДИ). Нормальность распределения показателей проверяли с помощью критерия Стьюдента. Для оценки различий между двумя независимыми выборками проводился статистический анализ с помощью t-теста. Корреляционный анализ проводили с использованием ранговой корреляции Спирмена. Величина уровня статистической значимости р принята равной 0,05.

РЕЗУЛЬТАТЫ

Объекты (участники) исследования

В исследование включены 53 пациента с разнообразной бронхолегочной патологией, которые были разделены на две группы:

  • первую группу составили 29 пациентов с вентиляционными нарушениями обструктивного типа среднетяжелой степени, установленной с помощью традиционных методов исследования функции внешнего дыхания, из них 26 (90%) мужчин и 3 (10%) женщины в возрасте от 42 до 89 лет (средний возраст 66±10 лет);
  • вторую группу (группу сравнения) составили 24 пациента, у которых показатели легочной вентиляции (спирометрии и бодиплетизмографии) сохранялись в пределах нормальных значений, из них 17 (71%) мужчин и 7 (29%) женщин в возрасте от 18 до 68 лет (средний возраст 33±12 лет).

Распределение обследованных пациентов обеих групп по диагнозам представлено в табл. 1, 2.

Курящие или бывшие курильщики составляли 90% в 1-й группе пациентов и 54% ― во 2-й. Таким образом, по признаку «табакокурение» группы были неоднородными.

Значения показателей механики дыхания и ИОМ у больных первой и второй групп представлены в табл. 3.

 

Таблица 1. Распределение пациентов первой группы по диагнозам

Диагноз

Всего

по группе (n=29)

Число

обследованных, %

Хроническая обструктивная болезнь легких

16

55

Бронхиальная астма

6

21

Хронический бронхит

5

17

Другие состояния

2

7

 

Таблица 2. Распределение пациентов второй группы по диагнозам

Диагноз

Всего

по группе (n=29)

Число

обследованных, %

Саркоидоз

13

54,0

Хронический бронхит

5

21

Другие состояния*

6

25

Примечание. * по одному случаю внебольничной пневмонии, бронхиолита, экспираторного стеноза трахеи, буллезной болезни, сосудистой трансформации верхней доли правого легкого, идиопатического гемосидероза легких.

 

Таблица 3. Показатели механики дыхания и импульсной осциллометрии

Показатель

1-я группа

n=29

2-я группа

n=24

p

М±SD (95% ДИ)

М±SD (95% ДИ)

ЖЕЛ, % долж.

91±14 (85–96)

110±10 (106–115)

<0,001

ФЖЕЛ, % долж.

76±11 (72–81)

112±10 (108–117)

<0,001

ОФВ1, % долж.

54±2,6 (53–54)

110±9 (106–114)

<0,001

ОФВ1/ЖЕЛ, %

46±7 (43–49)

81±5 (78–83)

<0,001

ОФВ1/ФЖЕЛ, %

56±8 (53–59)

82±4 (80–84)

<0,001

СОС25–75, % долж.

25±5 (23–27)

94±14 (88–100)

<0,001

ОЕЛ, % долж.

108±16 (101–114)

107±7 (104–110)

0,76

ВГО, % долж.

119±27 (109–129)

107±13 (101–112)

0,04

ООЛ, % долж.

144±33 (132–157)

99±10 (95–104)

<0,001

ООЛ/ОЕЛ, % долж.

125±15 (119–130)

90±10 (86–94)

<0,001

Rawобщ, кПа·с/л

0,65±0,20 (0,57–0,72)

0,21±0,04 (0,19–0,23)

<0,001

Rawвыд, кПа·с/л

0,90±0,35 (0,77–1,04)

0,24±0,04 (0,22–0,26)

<0,001

Rawвд, кПа·с/л

0,47±0,14 (0,4–0,5)

0,17±0,03 (0,15–0,18)

<0,001

Raw0.5, кПа·с/л

0,35±0,11 (0,30–0,39)

0,15±0,04 (0,14–0,17)

<0,001

Zrs5, % долж.

213±61 (190–200)

90±22 (81–100)

<0,001

Rrs5, % долж.

189±50 (170–208)

86±22 (77–95)

<0,001

Rrs20, % долж.

123±25 (113–132)

94±23 (84–103)

<0,001

(Rrs5-Rrs20)/Rrs5, %

43±8 (39–45)

7±7 (4–10)

<0,001

(Rrs5-Rrs20)/Rrs20, %

77±26 (67–87)

8±8 (4–12)

<0,001

(Rrs5-Rrs20), кПа·с/л

0,25±0,10 (0,2–0,3)

0,02±0,02 (0,01–0,03)

<0,001

deltaXrs5, кПа·с/л

0,27±0,13 (0,2–0,3)

0,08±0,03 (0,06–0,09)

<0,001

АХ, кПа/л

2,8±1,3 (2,3–3,3)

0,14±0,07 (0,11–0,17)

<0,001

DXrs5, кПа·с/л

0,33±0,27 (0,23–0,44)

0,02±0,02 (0,01–0,025)

<0,001

Со5

0,7±0,10 (0,70–0,76)

0,85±0,05 (0,83–0,88)

<0,001

fres, Гц

25±3,6 (24–26)

9±1 (8–10)

<0,001

Примечание. Расшифровка аббревиатур показателей приведена в разделе «Методы».

 

ОБСУЖДЕНИЕ

Анализ представленных данных показал, что у больных с вентиляционными нарушениями обструктивного типа среднетяжелой степени достоверно снижены показатели ОФВ1/ЖЕЛ, ОФВ1/ФЖЕЛ, ОФВ1, ФЖЕЛ, СОС25–75, повышены — ООЛ и ООЛ/ОЕЛ. Кроме того, увеличены показатели бронхиального сопротивления: Rawобщ ― резко, Rawвыд ― значительно, Rawвд и Raw0.5 ― умеренно. В пределах нормальных значений находились ЖЕЛ, ОЕЛ и ВГО.

По данным ИОМ у пациентов первой группы все изученные параметры были патологически изменены. У 93% пациентов выявлены отклонения от нормы базовых показателей Rrs5 и Xrs5: у 8 (27,5%) ― легкой, у 8 (27,5%) ― умеренной, у 2 (7%) ― тяжелой, 9 (31%) ― крайне тяжелой степени выраженности. У 2 (7%) пациентов базовые показатели ИОМ оставались в пределах нормальных значений, однако были увеличены абсолютная и относительная частотная зависимость, АХ и fres. Показатель Со5 в среднем по группе находился в пределах нормальных значений, что позволяло судить об отсутствии патологической неоднородности механических свойств аппарата вентиляции у больных со среднетяжелой степенью обструкции дыхательных путей.

Анализ параметров механики дыхания и ИОМ в группе сравнения показал отсутствие каких-либо отклонений от нормальных значений (см. табл. 3).

Были выявлены статистически значимые различия показателей спирометрии, бодиплетизмографии, а также параметров дыхательного импеданса в двух группах, которые оценивали с помощью t-теста (см. табл. 3).

При корреляционном анализе по Спирмену в 1-й группе были выявлены умеренные прямые корреляционные зависимости показателей Rawобщ и Rawвыд с Rrs5, (Rrs5-Rrs20)/Rrs5, (Rrs5-Rrs20)/Rrs20, (Rrs5-Rrs20), deltaXrs5, АХ, fres, DXrs5, а также со степенью выраженности изменений параметров ИОМ (рис., изображение А).

Таким образом, у больных с вентиляционными нарушениями обструктивного типа среднетяжелой степени показатели бронхиального сопротивления дыхательных путей общего и на выдохе находились в умеренной прямой корреляционной зависимости с большинством изученных параметров ИОМ, за исключением Rrs20, который находился в обратной умеренной корреляционной зависимости с ОФВ1(см. рис., изображение Б).

 

Рис. Ранговая корреляция Спирмена

Примечание. Выявлены умеренные прямые корреляционные зависимости между традиционными показателями исследования функции внешнего дыхания — Rawобщ (А) и ОФВ1 (Б) и показателями импульсной осциллометрии — степенью выраженности изменений параметров ИОМ (А) и Rrs20 (Б).

 

ЗАКЛЮЧЕНИЕ

При использовании классического алгоритма интерпретации показателей ИОМ среднетяжелая обструкция дыхательных путей, диагностированная с помощью традиционных методов исследования функции внешнего дыхания, была выявлена у 93% пациентов. Выраженность обструктивных вентиляционных нарушений по данным ИОМ не всегда совпадает с выраженностью нарушений, определяемых при помощи спирометрии: у 37% пациентов со среднетяжелой степенью обструкции дыхательных путей тяжесть выявленных с помощью ИОМ нарушений механики дыхания была более выражена.

×

About the authors

O. I. Savushkina

Acad. N.N. Burdenko Main Military Clinical Hospital, Ministry of Defense

Author for correspondence.
Email: olga-savushkina@yandex.ru

PhD, Head of Department of Lung Function Testing, Center of Functional Diagnostic Investigations

Russian Federation, 3, Gospitalnaya square, Moscow, 105229

A. V. Chernyak

Research Institute of Pulmonology of the Federal Medical-Biological Agency of Russia

Email: achi2000@mail.ru
ORCID iD: 0000-0002-2001-5504
SPIN-code: 9328-6440

PhD, Head of the Laboratory of Functional and Ultrasonic Research Methods

Russian Federation, 115682, Moscow, Orekhovy Boulevard, d. 28

E. V. Kryukov

Acad. N.N. Burdenko Main Military Clinical Hospital, Ministry of Defense

Email: evgeniy.md@mail.ru
SPIN-code: 3900-3441

докт. мед. наук, профессор, член-корреспондент РАН; начальник

Russian Federation, 3, Gospitalnaya square, Moscow, 105229

A. A. Zaytsev

Acad. N.N. Burdenko Main Military Clinical Hospital, Ministry of Defense

Email: a-zaicev@yandex.ru
ORCID iD: 0000-0002-0934-7313
SPIN-code: 6549-5154

докт. мед. наук, профессор, главный пульмонолог

Russian Federation, 3, Gospitalnaya square, Moscow, 105229

Zh. K. Naumenko

Research Institute of Pulmonology of the Federal Medical-Biological Agency of Russia

Email: naumenko_janna@mail.ru
SPIN-code: 7191-1758

канд. мед. наук, старший научный сотрудник лаборатории функциональных и ультразвуковых методов исследования

Russian Federation, 28, Orekchovy Boulevard, Moscow, 115682 

A. R. Tatarsky

Research Institute of Pulmonology of the Federal Medical-Biological Agency of Russia

Email: aleksey.tatarsky@gmail.com

докт. мед. наук, профессор, руководитель образовательного центра

Russian Federation, 28, Orekchovy Boulevard, Moscow, 115682

References

  1. Каменева М.Ю., Савушкина О.И., Черняк А.В. Импульсная осциллометрия. В кн.: Легочные функциональные тесты: от теории к практике. Руководство для врачей. / Под ред. О.И. Савушкиной, А.В. Черняка. — М.; 2017. — С. 121–148. [Kameneva MYu, Savushkina OI, Chernyak AV. Impul’snaya ostsillometriya. In: Legochnye funktsional’nye testy: ot teorii k praktike. Rukovodstvo dlya vrachei. Ed by O.I. Savushkinа, A.V. Chernyak. Moscow: 2017. рр. 121–148. (In Russ).]
  2. Brashier B, Salvi S. Measuring lung function using sound waves: role of the forced oscillation technique and impulse oscillometry system. Breathe. 2015;11(1):57–65. doi: 10.1183/20734735.020514.
  3. Савушкина О.И., Черняк А.В., Каменева М.Ю., и др. Возможности импульсной осциллометрии в диагностике обструкции дыхательных путей легкой степени выраженности // Пульмонология. — 2018. — Т.28. — №4 — С. 391–398. [Savushkina OI, Chernyak AV, Kameneva MYu, et al. A role of impulse oscillometry for diagnosis of mild bronchial obstruction. Pul`monologiya. 2018;28(4):391–398. (In Russ).] doi: 10.18093/0869-0189-2018-28-4-391-398.
  4. Савушкина О.И., Черняк А.В., Каменева М.Ю., и др. Диагностика обструкции дыхательных путей умеренной степени выраженности методом импульсной осциллометрии // Медицинский алфавит. Серия «Современная функциональная диагностика». — 2018. — Т.3. — №25 — С. 40–44. [Savushkina OI, Cherniak AV, Kameneva MYu, et al. Diagnosis of airway obstruction of moderate severity by the method of pulsed oscillometry. Medical Alphabet. 2018;3(25):40–44. (In Russ).]
  5. Miller MR, Hankinson J, Brusasco V, et al.; ATS/ERS Task Force. Standardisation of spiro-metry. Eur Respir J. 2005;26(2):319–338. doi: 10.1183/09031936.05.00034805.
  6. Wanger J, Clausen JL, Coates A, et al. Standar-disation of the measurement of lung volumes. Eur Respir J. 2005;26(3):511–522. doi: 10.1183/09031936.05.00035005.
  7. Чучалин А.Г., Айсанов З.Р., Чикина С.Ю., и др. Федеральные клинические рекомендации Российского респираторного общества по использованию метода спирометрии // Пульмонология. — 2014. — №6 —С. 11–23. [Chuchalin AG, Aisanov ZR, Chikina SYu, et al. Federal’nye klinicheskie rekomendatsii Rossiiskogo respiratornogo obshchestva po ispol’zovaniyu metoda spirometrii. Pul`monologiya. 2014;(6):11–23. (In Russ).]
  8. Smith HJ, Reinhold P, Goldman MD. Forced oscillation technique and impulse oscillometry. Lung function testing: European Respiratory Society Monograph. Sheffield, England: European Respiratory Society; 2005. рр. 72–105.
  9. Руководство по клинической физиологии дыхания. / Под ред. Л.Л. Шика, Н.Н. Канаева. — Л.: Медицина; 1980. — 376 с. [Rukovodstvo po klinicheskoi fiziologii dykhaniya. Ed by L.L. Shik, N.N. Kanaev. Leningrad: Meditsina; 1980. 376 p. (In Russ).]
  10. Winkler J, Hagert-Winkler A, Wirtz H, Hoheisel G. [Modern impulse oscillometry in the spectrum of pulmonary function testing methods. (Article in German)]. Pneumologie. 2009;63(8):461–469. doi: 10.1055/s-0029-1214938.
  11. Pellegrino R, Viegi G, Brusasco V, et al. Interpretative strategies for lung function tests. Eur Respir J. 2005;26(5):948–968. doi: 10.1183/09031936.05.00035205.

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. Spearman's rank correlation

Download (62KB)

Copyright (c) 2018 Savushkina O.I., Chernyak A.V., Kryukov E.V., Zaytsev A.A., Naumenko Z.K., Tatarsky A.R.

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 38032 от 11 ноября 2009 года.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies