BIOELECTRIC IMPEDANCEMETRY AS A METHOD OF ASSESSMENT OF THE MYOCARDIUM DURING OPEN-HEART SURGERY

Cover Page


Cite item

Full Text

Abstract

The article analyses the possibility of using direct bioelectric impedancemetry of the right ven- tricle (RV) as an intra-operation method for evaluation of myocardial protection effectiveness in open-heart surgery. The results of intra-operation monitoring of bioelectric impedancemetry indi- cators of RV in 40 patients underwent surgical treatment with the use of cardioplegia were ana- lyzed. Bioelectrical impedance of myocardium has been studied during the whole period of artificial blood circulation. The analysis of the results showed that the bioelectric myocardium impedancemetry allows to assess the level of the interstitial space filling during the infusion of cardioplegia solution, providing an opportunity to assess the perfusion adequacy and also the level of reperfusion cells damage and myocardium swelling degree at the stage of coronary blood flow restoration. Using the method of myocardium bioelectric impedancemetry we found that blood cardioplegia with the "thermal induction" more reliably protects the myocardium in the period of anoxia in comparison with the cold cardioplegia.

Full Text

БИОЭЛЕКТРИЧЕСКАЯ ИМПЕДАНСОМЕТРИЯ КАК МЕТОД ОЦЕНКИ СОСТОЯНИЯ МИОКАРДА ВО ВРЕМЯ ОПЕРАЦИИ НА ОТКРЫТОМ СЕРДЦЕ
×

About the authors

V A Bubnov

Email: va66@mail.ru

D V Puzenko

Email: dpuzenko@yandex.ru

References

  1. Schaefer M., Knapp J., Gross W. et al. Measurement of electrical cell uncoupling in ischemic mouse heart// University of Heidelberg, Dept. of Experimental Surgery, INF 365, D-69120 Heidelberg, Germany. XII International Conference on Electrical Bio-Impedance - ICEBI Gdansk 2004.
  2. Бокерия Л.А., Бледжянц Г.А., Муратов P.M. и др. Электрическая импедансметрия как метод оценки защиты миокарда при операциях на сердце с искусственным кровообращением // Бюллетень НЦ ССХ им. А.Н. Бакулева РАМН Сердечно-сосудистые заболевания. 2006. Т. 7. № 5. С. 80-89.
  3. Бокерия Л.A., Бледжянц Г.А., Мовсесян P.P. и др. Биоэлектрическая импедансметрия миокарда при операциях на сердце с искусственным кровообращением // Бюллетень экспериментальной биологии и медицины. 2007. Т. 143. №1, С. 38-41.
  4. Бледжянц Г.А., Муратов P.M., Мовсесян P.P., и др. Биоэлектрическая иммпедансметрия миокарда в оценке эффективности защиты миокарда //Грудная и серд.-сосуд. хир. 2006. № 5. С. 19-22.
  5. Howie M, Dzwonczyk R, McSweene T. An evaluation of a new two-electrode myocardial electrical impedance monitor for detecting myocardial ischemia //Anesth Analg 2001;92:12-18.
  6. Wtorek J., Siebert J., Rogowski J. Electrical impedance spectroscopy as an estimator of heart muscle ischemia: in vitro study//Proc of Eur Med Biol. Eng Conf, in Med Biol Eng Comput incorp. Cell Eng. 1999. vol. 37, suppl. 2, pp. 90-91, 1999.
  7. Seoane F, Lindecrantz K, Olsson T, Kjellme I. Bioelectrical impedance during hypoxic cell swelling: modelling of tissue as a suspension of cells: in vitro study//Proc of Eur Med Biol. Eng Conf, in Med Biol Eng Comput. incorp. Cell Eng. 2005. vol.98, suppl. 3, pp. 73-78.
  8. Kink A, Min M, Parve T, Riitsep T Bioimpedance based analysis of tissue oedema: in vitro study//Proc of Eur Med Biol Eng Conf, in Med Biol Eng Comput incorp. Cell Eng. 2005. vol.98, suppl. 3, pp. 29-32.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2012 Bubnov V.A., Puzenko D.V.

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 38032 от 11 ноября 2009 года.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies