Standardized A-echography in the diagnostics of eye diseases
- 作者: Bedretdinov A.N.1, Kiseleva T.N.1
-
隶属关系:
- Helmholtz National Medical Research Center of Eye Diseases
- 期: 卷 17, 编号 3 (2024)
- 页面: 59-67
- 栏目: Lectures
- ##submission.dateSubmitted##: 05.05.2023
- ##submission.dateAccepted##: 09.04.2024
- ##submission.datePublished##: 23.09.2024
- URL: https://journals.eco-vector.com/ov/article/view/383558
- DOI: https://doi.org/10.17816/OV383558
- ID: 383558
如何引用文章
详细
The development and the improvement of new imaging methods are current trends in ophthalmology. The literature review is devoted to the use of standardized A-echography in the diagnostics of ocular pathology. The history of the development of this method, the basic principles of obtaining A-sonograms, the features of the qualitative and quantitative assessments of pathological changes in the structures of the eye based on echographic data are presented. Standardized A-echography is most widely used in the diagnostics of vitreoretinal pathology, intraocular mass (choroidal melanoma, choroidal hemangioma, non-tumor formations) and assessment of orbital structures (optic nerve, extraocular muscles, orbital tumors).
全文:

作者简介
Aleksei Bedretdinov
Helmholtz National Medical Research Center of Eye Diseases
编辑信件的主要联系方式.
Email: anbedretdinov@gmail.com
ORCID iD: 0000-0002-2947-1143
SPIN 代码: 1714-7669
MD, Cand. Sci. (Medicine)
俄罗斯联邦, MoscowTatiana Kiseleva
Helmholtz National Medical Research Center of Eye Diseases
Email: tkisseleva@yandex.ru
ORCID iD: 0000-0002-9185-6407
SPIN 代码: 5824-5991
MD, Dr. Sci. (Medicine), Professor
俄罗斯联邦, Moscow参考
- Mundt GH, Hughes WF. Ultrasonics in ocular diagnosis. Am J Ophthalmol. 2018;189:xxviii–xxxvi. doi: 10.1016/j.ajo.2018.02.017
- Ossoinig KC. Standardized echography: basic principles, clinical applications, and results. Int Ophthalmol Clin. 1979;19(4): 127–210.
- Ossoinig KC. Standardized ophthalmic echography of the eye, orbit, and periorbital region. A comprehensive slide set and study guide. 3rd ed. Iowa City: Goodfellow; 1985. P. 12.
- Byrne SF, Green RL. Ultrasound of the eye and orbit. Philadelphia: Mosby Inc; 2002. P. 244–273.
- Kendall CJ, Prager TC, Cheng H, et al. Diagnostic ophthalmic ultrasound for radiologists. Neuroimaging Clin N Am. 2015;25(3): 327–365. doi: 10.1016/j.nic.2015.05.001
- Karolczak-Kulesza M, Rudyk M, Niestrata-Ortiz M. Recommendations for ultrasound examination in ophthalmology. Part II: Orbital ultrasound. J Ultrason. 2018;18(75):349–354. doi: 10.15557/JoU.2018.0051
- Silverman RH. Focused ultrasound in ophthalmology. Clin Ophthalmol. 2016;10:1865–1875. doi: 10.2147/OPTH.S99535
- Fioretto I, Capuano FM, Biondino D, et al. Systematic use of standardized A-scan technique in neurosurgical intensive care unit. Quant Imaging Med Surg. 2023;13(10):7396–7397. doi: 10.21037/qims-23-628
- Vitiello L, De Bernardo M, Capasso L, Rosa N. Optic nerve ultrasound evaluation in acute high altitude illness. Wilderness Environ Med. 2021;32(3):407–408. doi: 10.1016/j.wem.2021.04.009
- Marotta G, Vitiello L, De Bernardo M, Rosa N. Ocular ultrasound evaluation in the acutely painful red eye. J Emerg Med. 2020;59(3):446–447. doi: 10.1016/j.jemermed.2020.04.061
- Singh N, Fonkeu Y, Lorek BH, Singh AD. Diagnostic A-scan of choroidal tumors: comparison of quantified parameters. Ocul Oncol Pathol. 2019;5(5):358–368. doi: 10.1159/000495350
- Samoila O. Is there a place for A-scan mode in modern eye ultrasonography? Med Ultrason. 2019;21(4):498–499. doi: 10.11152/mu-2157
- Mithal KN, Thakkar HH, Tyagi MA, et al. Role of echography in diagnostic dilemma in choroidal masses. Indian J Ophthalmol. 2014;62(2):167–170. doi: 10.4103/0301-4738.128626
- Rosa N, De Bernardo M, Di Stasi M, et al. A-scan ultrasonographic evaluation of patients with idiopathic intracranial hypertension: comparison of optic nerves. J Clin Med. 2022;11(20):6153. doi: 10.3390/jcm11206153
- De Bernardo M, Vitiello L, De Pascale I, et al. Optic nerve ultrasound evaluation in idiopathic intracranial hypertension. Front Med (Lausanne). 2022;9:845554. doi: 10.3389/fmed.2022.845554
- Vitiello L, De Bernardo M, Capasso L, et al. Optic nerve ultrasound evaluation in animals and normal subjects. Front Med (Lausanne). 2022;8:797018. doi: 10.3389/fmed.2021.797018
- De Bernardo M, Vitiello L, De Luca M, et al. Optic nerve changes detected with ocular ultrasonography during different surgical procedures: a narrative review. J Clin Med. 2022;11(18):5467. doi: 10.3390/jcm11185467
- Blumenkranz MS, Byrne SF. Standardized echography (ultrasonography) for the detection and characterization of retinal detachment. Ophthalmology. 1982;89(7):821–831. doi: 10.1016/s0161-6420(82)34716-8
- Ossoinig KC. Echographic detection and classification of posterior hyphemas. Ophthalmologica. 1984;189(1–2):2–11. doi: 10.1159/000309378
- McLeod D, Restori M. Ultrasonic examination in severe diabetic eye disease. Br J Ophthalmol. 1979;63(8):533–538. doi: 10.1136/bjo.63.8.533
- Hermsen V. The use of ultrasound in the evaluation of diabetic vitreoretinopathy. Int Ophthalmol Clin. 1984;24(4):125–141.
- Byrne SF. Standardized echography of the eye and orbit. Neuroradiology. 1986;28(5–6):618–640. doi: 10.1007/BF00344110
- Ossoinig KC. Ruling out posterior segment lesions with echography. Int Ophthalmol Clin. 1978;18(2):117–120.
- Pulido JS, Byrne SF, Clarkson JG, et al. Evaluation of eyes with advanced stages of retinopathy of prematurity using standardized echography. Ophthalmology. 1991;98(7):1099–1104. doi: 10.1016/s0161-6420(91)32171-7
- Genovesi-Ebert F, Rizzo S, Chiellini S, et al. Reliability of standardized echography before vitreoretinal surgery for proliferative diabetic retinopathy. Ophthalmologica. 1998;212(Suppl 1):91–92. doi: 10.1159/000055438
- Fonkeu Y, Singh N, Hayden-Loreck B, Singh AD. Diagnostic A-scan of choroidal melanoma: automated quantification of parameters. Ocul Oncol Pathol. 2019;5(5):350–357. doi: 10.1159/000496345
- Ossoinig KC, Bigar F, Kaefring SL. Malignant melanoma of the choroid and ciliary body. A differential diagnosis in clinical echography. Bibl Ophthalmol. 1975;(83):141–154.
- Hodes BL, Choromokos E. Standardized A-scan echographic diagnosis of choroidal malignant melanomas. Arch Ophthalmol. 1977;95(4):593–597. doi: 10.1001/archopht.1977.04450040059006
- Fuller DG, Snyder WB, Hutton WL, Vaiser A. Ultrasonographic features of choroidal malignant melanomas. Arch Ophthalmol. 1979;97(8):1465–1472. doi: 10.1001/archopht.1979.01020020127008
- Farah ME, Byrne SF, Hughes JR. Standardized echography in uveal melanomas with scleral or extraocular extension. Arch Ophthalmol. 1984;102(10):1482–1485. doi: 10.1001/archopht.1984.01040031202018
- Rochels R, Nover A. Small choroidal melanoma with diffuse orbital involvement detected and differentiated with standardized echography — with special reference to the reliability of sonography in predicting scleral tumoral infiltration. Ophthalmologica. 1986;192(1):39–45. doi: 10.1159/000309610
- Kim RS, Jain RR, Brown DM, et al. Elevated choroidal thickness and central serous chorioretinopathy in the fellow eyes of patients with circumscribed choroidal hemangioma. Ocul Oncol Pathol. 2018;4(6):375–380. doi: 10.1159/000486864
- Campagnoli TR, Medina CA, Singh AD. Choroidal melanoma initially treated as hemangioma: diagnostic and therapeutic considerations. Retin Cases Brief Rep. 2016;10(2):175–182. doi: 10.1097/ICB.0000000000000220
- Mrejen S, Fung AT, Silverman RH, et al. Potential pitfalls in measuring the thickness of small choroidal melanocytic tumors with ultrasonography. Retina. 2013;33(7):1293–1299. doi: 10.1097/IAE.0b013e318296f681
- Piñeiro-Ces A, Rodríguez Alvarez MJ, Santiago M, et al. Detecting ultrasonographic hollowness in small choroidal melanocytic tumors using 10 MHz and 20 MHz ultrasonography: a comparative study. Graefes Arch Clin Exp Ophthalmol. 2014;252(12):2005–2011. doi: 10.1007/s00417-014-2758-4
补充文件