Open Access Open Access  Restricted Access Access granted  Restricted Access Subscription or Fee Access

Vol 106, No 4 (2017)

Full Issue

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Articles

pages 4-9 views

Novoe pokolenie promyshlennykh pilotnykh regulyatorov

Sukhov E.V., Kazulin M.V.
Refrigeration Technology. 2017;106(4):10-13
pages 10-13 views

Kholodil'noe oborudovanie dlya pishchevykh promyshlennykh proizvodstv. Tendentsii i innovatsii

Pecherskikh K.V.
Refrigeration Technology. 2017;106(4):14-16
pages 14-16 views

Teploobmenniki ECO kompanii Modine

- -.
Refrigeration Technology. 2017;106(4):17-17
pages 17-17 views

Vintovye kompressory Fusheng v Rossii

Spasskiy A.A., Spasskiy I.A., Sushentseva A.V.
Refrigeration Technology. 2017;106(4):18-23
pages 18-23 views

Povyshenie kvalifikatsii s Emerson

Talyzin M.S.
Refrigeration Technology. 2017;106(4):24-27
pages 24-27 views
pages 28-28 views

Sdelano v Rossii: programmnotekhnicheskie sredstva monitoringa mikroklimata

- -.
Refrigeration Technology. 2017;106(4):29-34
pages 29-34 views

Raschetnoe obosnovanie parametrov mikroklimata s zadannym urovnem teplovogo komforta

Sulin A.B., Ryabova T.V., Ivanov S.V., Poddubnyy R.A.

Abstract

The article analyses the issues of the calculation technique applicability for the predetermined level of thermal comfort in accordance with the requirements of ISO 7730. The air temperature as a function of humidity, speed, the radiation temperature difference was calculated for different values of metabolic and clothing thermal insulation rate. The results are given in tabular and graphical form as well as in the form of approximating polynomials. The calculations are performed for class B rooms. The range of expected thermal sensations is from «slightly cool» to «slightly warm» for the following ranges of parameters: the rate of metabolism 68-177 W/m2, clothing thermal resistance 0,108-0,202 m2·K/W, air velocity 0,1-0,7 m/s, relative humidity 20-80 %, radiation temperature difference -8…+8 °С. The dependences obtained for the parameters of the microclimate, providing a given level of thermal comfort, can be used to support energy efficient modes of operation of air conditioning systems.
Refrigeration Technology. 2017;106(4):35-39
pages 35-39 views

Teplovaya izolyatsiya dlya kholodil'nykh truboprovodov na predpriyatiyakh APK

Shipulina I.A., Kornienko V.N., Chernyak V.A.

Abstract

Refrigeration pipelines through which generated artificial cold is transported from the production site to the consumption place by means of a heattransfer agent are the most used objects to heat insulation apply. The correct choice and proper makingup of heat insulation influence directly the power efficiency and the duration of safe exploitation of tubes under adverse temperatures and humid conditions. A qualitative assembly of the tube insulation decreases significantly the wear and tear of refrigeration pipelines and minimizes the tubes frostingup as well as contributes to reducing the frequency of changing separate outofoperation parts of pipelines and multipurpose valves. The paper analyses qualities and defects of series of heat insulating materials, the particularities of assemblage and exploitation of heat protective constructions based on them are examined as well. Modern heat-insulating materials and products based on RU -FLEKS foamed synthetic rubber (Russian production of a complete cycle using domestic technologies and raw materials) are cited in detail; they have been developed and produced within the framework of the main terms of the import substitution of State Program № 328 “Development of industry and rise of competitiveness” of April 15, 2014.
Refrigeration Technology. 2017;106(4):40-47
pages 40-47 views
pages 48-50 views

Tri klimaticheskikh kita industrii kholoda. Dominanty ustoychivosti i sindromy netraditsionnogo razvitiya

Tsvetkov O.B., Laptev Y.A.

Abstract

На мегафакультете «Биотехнологии и низкотемпературные системы» СанктПетербургского национального исследовательского университета информационных технологий, механики и оптики (Университет ИТМО) 1 февраля 2017 г. прошла научнотехническая конференция с международным участием «Три климатических кита индустрии холода. Доминанты устойчивости и синдромы нетрадиционного развития». Организаторы конференции: Международная академия холода (МАХ), Рабочая группа «Свойства хладагентов и теплоносителей» Национального комитета по теплофизическим свойствам веществ РАН (Университет ИТМО). Информационную поддержку осуществляли журналы «Вестник Международной академии холода», «Холодильная техника», «Холодильный бизнес», «Империя холода», интернетпортал «РефПортал». Генеральные спонсоры конференции: ЗАО «Инженерные системы охлаждения», ООО «А и Т» и Инженерный центр энергоэффективных холодильных технологий и автоматики (СанктПетербург). В конференции участвовали организации и высшие учебные заведения: Институт теплои массообмена им. А.В. Лыкова НАН Беларуси, ООО «Центр озонобезопасных технологий» (Минск, Беларусь), Алматинский технологический университет (Казахстан), ООО «Тениз» (Алматы, Казахстан), Институт холода, криотехнологий и экоэнергетики им. В.С. Мартыновского Одесской национальной академии пищевых технологий (Украина), Забайкальский государственный университет (г. Чита), Астраханский технический университет, ООО «Рудетранссервис» (Великий Новгород), ВосточноСибирский государственный университет технологий и управления (УланУдэ), АО «Транснефть-Сибирь» (Тюмень), Новочарская дистанция пути ВСЖД (Новая Чара, Читинская обл.), ФГБНУ «ВНИХИ», ООО «ТрансИГЭМ», ООО «НПП «Медгаз», Национальный исследовательский ядерный университет «МИФИ», НИУ «МЭИ (ТУ)», ООО «НЕДЦентр», Московский политехнический университет (МПУ), Московский государственный университет пищевых производств (МГУПП), ООО «НПО «Север» (все - Москва), ОАО «Гипрорыбфлот», ООО «А и Т», Инженерный центр энергоэффективных холодильных технологий и автоматики, Университет ИТМО (все - СанктПетербург), преподаватели, научные сотрудники, аспиранты, докторанты, магистранты и бакалавры старших курсов.
Refrigeration Technology. 2017;106(4):51-53
pages 51-53 views
pages 54-60 views

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies