开放存取 开放存取  受限制的访问 ##reader.subscriptionAccessGranted##  受限制的访问 订阅或者付费存取

卷 80, 编号 11 (2025)

封面

完整期次

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅或者付费存取

REVIEWS

Miniaturized methods for isolation and preconcentration: micro-solid-phase extraction and solid-phase microextraction of organic compounds. A review of reviews

Dmitrienko S., Apyari V., Tolmacheva V., Matyash M., Furletov A., Zolotov Y.

摘要

Miniaturized methods for sorptive isolation and preconcentration of organic compounds include micro-solid-phase extraction (μ-SPE) and solid-phase microextraction (SPME). These methods are characterized by reduced amounts of sorbents, analyzed samples, and organic solvents, high preconcentration factors, and the integration of preconcentration and sample introduction into a single device. Since the emergence of μ-SPE (1989) and SPME (1990), numerous variants of these methods have been developed, differing in sample preparation techniques, the nature of the sorbents used, and their integration with subsequent determination methods. The popularity of these methods is evidenced by the large number of reviews summarized in this publication.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1119-1140
pages 1119-1140 views

ORIGINAL ARTICLES

Phytochemical analysis of extracts from several plants growing in Russia using deep eutectic solvents

Bochko T., Ogrenich N., Malyshko M., Shishov A.

摘要

Medicinal plants are an important source of biologically active compounds used in medicine for the prevention and treatment of various diseases. The main classes of such compounds—alkaloids, glycosides, flavonoids, essential oils, tannins, polyphenols, and polysaccharides—exhibit a wide range of pharmacological activities (antimicrobial, anti-inflammatory, antiseptic, antioxidant, etc.). Phytochemical screening of plant extracts is essential for identifying these compounds and developing new highly active therapeutic agents. Spectrophotometric phytochemical screening was conducted for alkaloids, tannins, flavonoids, phenolic compounds, steroidal cardiac glycosides, and polysaccharides, along with the determination of antioxidant activity in extracts of three medicinal plants from different families: milky ripe oats (Avena sativa L.), madder root (Rubia tinctorum L.), and common heather (Calluna vulgaris L.). High-performance liquid chromatography was employed for a more detailed analysis of the extracts. Both traditional solvents (methanol, ethanol, water-ethanol mixture, water, acetonitrile) and a new class of solvents—deep eutectic solvents—were used as extractants. Extraction of biologically active compounds was performed using ultrasound at 40–80 °C for 10–60 minutes. Optimal extraction conditions for the main compound groups were established: 80 °C and 60 minutes for traditional solvents; 50°C for 30 minutes (heather) and 60°C for 30 minutes (madder root and oats) when using deep eutectic solvents. Deep eutectic solvents enable the extraction of target bioactive compounds under milder conditions, demonstrating their potential as environmentally friendly extractants in phytochemical studies.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1141-1153
pages 1141-1153 views

Determination of Carbon in Carbonate-Silicate Glasses by X-Ray Spectral Microanalysis

Viryus A., Chevychelova V.

摘要

A method for determining carbon content in carbonate-aluminosilicate glasses using X-ray spectral microanalysis has been proposed and implemented. To account for the contribution of the non-useful signal from the conductive carbon layer and carbon deposits formed under the electron probe to the analytical signal of the CKα line, a calibration curve was constructed using carbonate standard samples with varying carbon content. The analytical signal was based on the calculated area under the first peak of the CKα line, which allowed consideration of the influence of chemical bonds formed by carbon with oxygen and other elements on the shape and position of the CKα line. Optimal conditions for recording X-ray spectra in the CKα line region were selected for subsequent carbon determination. Linear calibrations obtained at 5 kV using carbonate standards are highly reproducible, with a relative standard deviation (sr) of analytical signal values ranging from 1–3%. The calculated detection limits for carbon using the developed method are 0.2–0.4 wt.%, with the lower limit of quantifiable content being 0.6–1.2 wt.%.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1154-1162
pages 1154-1162 views

Challenges and Features of Polysaccharide Visualization in Sorbent Layers During Planar Chromatography

Malakhova I., Kirillov A., Gorshkov N., Eremin A., Krasikov V.

摘要

The features of planar (thin-layer) chromatography of several linear non-ionic polysaccharides (amylose, pullulan), their visualization by post-chromatographic derivatization with iodine, and the factors influencing this process are described. It is shown that the coloration of pullulan results from the formation of pseudoclathrate complexes of molecular iodine–iodide–pullulan in short helical segments of the polysaccharide, as well as iodine absorption in the bends of the polymer chain. It was established that the shift of the spectral absorption maximum of amylose (λmax ~ 600 nm, blue coloration) to the shorter wavelength region (λmax = 560 nm, red-brown coloration) is associated with specific interactions of starch with silica and the formation of a molecular iodine–iodide-anion–amylose–silica gel complex. It was demonstrated that the intensity of iodine staining of high-molecular-weight polysaccharides does not depend on their degree of polymerization, and polysaccharide visualization by the iodine reaction in thin-layer chromatography is possible only on neutral forms of silica sorbents.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1163-1174
pages 1163-1174 views

New hyperbranched zwitterionic sorbents for HPLC and methods for controlling their separation capacity

Chernobrovkina A., Kryzhanovskaya D., Uzhel A., Sobolev N., Tsizin G., Shpigun O.

摘要

A series of sorbents based on silica gel with zwitterionic functional layers attached via a spacer based on 1,4-butanediol diglycidyl ether was synthesized. The influence of structural fragments of the stationary phase on chromatographic properties in hydrophilic interaction chromatography was studied, and the multifunctional separation capabilities for neutral polar, hydrophobic, and negatively charged compounds were demonstrated. Based on the identified patterns, a sorbent with high separation capacity for carboxylic acids was developed, enabling the separation of 13 organic acids in 25 minutes with a resolution of at least 1.0.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1175-1188
pages 1175-1188 views

Retention patterns of alkali and alkaline earth metal cations on a carboxylic cation exchanger

Nesterenko P., Timina M., Krasheninina S., Stavrianidi A., Rozhmanova N.

摘要

The chromatographic retention features of alkali and alkaline earth metal cations on poly(styrene-divinylbenzene) cation exchangers with grafted carboxylic groups were investigated. It was found that the retention of metal cations with the same charge is directly proportional to their polarizability. The retention patterns of metal and ammonium cations were studied in relation to the nature and concentration of the eluent, and the contribution of secondary processes to retention and peak shape was determined. It was shown that increasing eluent concentration improves the symmetry of chromatographic peaks. Van’t Hoff dependencies were constructed, and the enthalpy values (ΔH°) of adsorption were calculated. It was noted that column efficiency increases with temperature. The possibility of simultaneous determination of alkali, alkaline earth metal, and ammonium cations by ion chromatography using carboxylic cation exchangers and two variants of conductometric detection was demonstrated. Practical applications of the sorbents are discussed.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1189-1205
pages 1189-1205 views

Analysis of the composition of certain phenolic carboxylic acids and terpenes in Juniperus communis L. fruits and needles by gas and liquid chromatography-mass spectrometry

Ermakov A., Bobkova N., Nesterova O., Nesterov G., Pirogov A., Chichkanova E., Ananyeva I., Prosuntsova D., Kuzmenko A.

摘要

Common juniper (Juniperus communis L., Cupressaceae family) is a promising source of biologically active compounds for the treatment and prevention of chronic diseases. Extracts of juniper needles and fruits were analyzed using high-resolution HPLC-MS and GC-MS with thermal desorption (TD). Six hydroxybenzoic acids and four hydroxycinnamic acids were identified on chromatograms obtained in full-scan mode. The content of salicylic, p-hydroxybenzoic, gallic, coumaric, and ferulic acids was estimated at 0.03–17 mg/L. In TD-GC-MS mode, peaks of compounds were recorded in the retention time range of 9–25 minutes (retention indices from 900 to 1700). For more reliable identification, experimental retention indices were calculated and compared with literature values. It was suggested that the presence of compounds such as cosmene, pinocarveol, and 2-pinene-4-one in chromatograms may serve as markers of juniper fruit presence in needle-based dietary supplements.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1206-1213
pages 1206-1213 views

FEATURES OF GAS CHROMATOGRAPHIC IDENTIFICATION OF LOW-BOILING ORGANIC SOLVENTS. EVALUATION OF RETENTION INDEX INFORMATIVENESS

Zenkevich I.

摘要

The features of gas chromatographic identification of 80 common low-boiling organic solvents based on retention indices on standard non-polar polydimethylsiloxane stationary phases were examined. It was shown that one-dimensional analytical parameters, such as retention indices, cannot provide unambiguous identification of all compounds in this group, as the informativeness criterion R(RI) for this group is only about 29, which is less than the number of compounds. To address this issue, supplementing chromatographic data with independent characteristics, such as refractive indices (nD20), is recommended, as their determination requires minimal time and sample amounts. However, about 10% of the solvents cannot be distinguished even by combining RI and nD20. For comparison, the potential use of dynamic viscosity values as an additional analytical parameter was considered. The provided table of retention indices for the most common organic solvents is of independent value for analytical practice.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1214-1223
pages 1214-1223 views

ELISA ON MAGNETIC BEADS WITH ELECTROCHEMICAL DETECTION FOR NT-PROBNP ANALYSIS IN HUMAN BLOOD SERUM

Sorokina O., Konstantinova T., Vorobyova A., Vasilyeva A., Eremenko A., Lyzhenkova A., Zobova E., Minushkina L., Kurochkin I.

摘要

This article presents a new electrochemical method for enzyme-linked immunosorbent assay (ELISA) on magnetic microparticles functionalized with antibodies specific to the cardiac biomarker NT-proBNP. Alkaline phosphatase was chosen as the enzyme label. Signal detection was performed using differential pulse voltammetry on disposable electrodes. The method is characterized by high sensitivity, with a detection limit of ~35 pg/mL, and a short analysis time of up to 20 minutes, making it promising for clinical practice. Optimization of key method parameters was carried out, including component concentrations, temperature, and incubation time. The method was tested on 34 samples of serum from healthy individuals and patients with cardiovascular diseases. To assess the method’s applicability in clinical practice, a correlation analysis was performed between the electrochemical signal intensities and concentration data obtained from the Mindray BS-800 and Getein-1100 analyzers. Statistical analysis revealed a high linear correlation between the signal obtained by the developed method and the target protein concentrations in the samples: correlation coefficients were 0.96 for Mindray BS-800 and 0.93 for Getein-1100.

Zhurnal Analiticheskoi Khimii. 2025;80(11):1224-1233
pages 1224-1233 views

CRITIQUE AND BIBLIOGRAPHY

Analytical Chemistry II. Springer, 2025

Zorov N.

摘要

""

Zhurnal Analiticheskoi Khimii. 2025;80(11):1234-1234
pages 1234-1234 views

EVENTS

XIII Всероссийская конференция по анализу объектов окружающей среды

Bulatov A., Zolotov Y.

摘要

""

Zhurnal Analiticheskoi Khimii. 2025;80(11):1235-1237
pages 1235-1237 views

Валентину Алексеевичу Крылову – 80 лет

Krylov V.

摘要

''

Zhurnal Analiticheskoi Khimii. 2025;80(11):1238-1239
pages 1238-1239 views

К юбилею Анатолия Ильича Сапрыкина

Saprykin A.

摘要

""

Zhurnal Analiticheskoi Khimii. 2025;80(11):1240-1240
pages 1240-1240 views