Morphometric parameters of the placenta and umbilical cord during full-term pregnancy


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Abstract

Objective. To define the diagnostic and prognostic value of the major morphometric parameters of the umbilical cord and placenta for full-term neonates. Subjects and methods. The investigation enrolled 123 full-term newborn infants. The length and diameter of the umbilical cord, the maximum and minimum diameters of the placenta, its weight and umbilical cord blood volume were measured immediately after delivery of the placenta. Results. The morphometric parameters of the umbilical cord and placenta during full-term pregnancy were found to show a rather wide range of values. One cm of the umbilical cord contained an average of 0.5 ml of blood and its amount sequestered in the entire umbilical cord averaged 29.97%, amounting to 9.52% of the neonatal circulating blood volume. The length of the umbilical cord was shown to be directly related to all major anthropometric parameters at birth: weight, height, head and chest circumferences. Its diameter was correlated with the specific features of the early neonatal period. Conclusion. The standards and values of placental and umbilical cord morphometric parameters were determined to predict the course of an early neonatal period. Calculating the amount of blood sequestered in the umbilical cord allows blood transfusion volume from the umbilical cord to a baby to be estimated immediately after birth.

Full Text

Restricted Access

About the authors

Anna L. Karpova

Yaroslavl State Medical University

Email: annal409@mail.ru
PhD, assistant of the Department of outpatient therapy and laboratory diagnosis, Institute of Postgraduate Education

Nikolay Yu. Karpov

Yaroslavl State Medical University

Email: karnikl965@gmail.com
obstetrician-gynecologist, Institute of Postgraduate Education

Alexey V. Mostovoy

Yaroslavl State Medical University

Email: info@neonatalspb.ru
PhD, assistant of the Department of outpatient therapy and laboratory diagnosis, Institute of Postgraduate Education

Nataljya N. Kondakova

Yaroslavl Regional Perinatal Center

Email: neo_natalya@mail.ru
Deputy Chief for pediatric care

References

  1. Кондакова Л.И. Органометрические показатели пуповины в норме и при патологии беременности. Успехи современного естествознания. 2009; 6: 34-8. [Kondakova L.I. Organometric indicators cord in normal and pathological pregnancy. Uspehi sovremennogo estestvoznaniya. 2009; 6: 34-8. (in Russian)]
  2. Baergen R.N., Malicki D., Behling C., Benirschke K. Morbidity, mortality, and placental pathology in excessively long umbilical cords: retrospective study. Pediatr. Dev. Pathol. 2001; 4(2): 144-53.
  3. Naeye R.L. Umbilical cord length: clinical significance. J. Pediatr. 1985; 107(2): 278-81.
  4. Raisanen S., Sokka A., Georgiadis L., Harju M., Gissler M., Keski-Nisula L. et al. Infertility Treatment and umbilical cord length-novel markers of childhood epilepsy? PLoS One. 2013; 8(2): e55394.
  5. Rabe H., Jewison A., Alvarez R.F., Crook D., Stilton D., Bradley R. et al. Milking compared with delayed cord clamping to increase placental transfusion in preterm neonates: a randomized controlled trial. Obstet. Gynecol. 2011; 117(2, Pt1): 205-11.
  6. Balkawade N.U., Shinde M.A. Study of length of umbilical cord and fetal outcome: a study of 1,000 deliveries. J. Obstet. Gynaecol. India. 2012; 62(5): 520-5.
  7. NuggedAlla M.A.A. A preliminary study on the morphological variations in the umbilical cord of sundanese. Time J. Med. Sci. Rep. Res. 2013; 1(2): 10-5.
  8. Proctor L.K., Fitzgerald B., Whittle W.L., Mokhtari N., Lee E., Machin G. et al. Umbilical cord diameter percentile curves and their correlation to birth weight and placental pathology. Placenta. 2013; 34(1): 62-6.
  9. Goswami P., Memon S., Channa M.A., Rathi H. Excessive calcification of placenta: To examine the morphological change in pregnancies complicated by PIH and placental abruption and its relation with fetal outcome. Professional Med. J. 2013; 20(5): 743-51.
  10. Petekkaya E., Deniz M., Yildiz E. Analysis of the relationship between umbilical cord placental morphology and anthropometric measurements of the newborn. Pak. J. Med. Sci. 2011; 27(3): 569-73.
  11. Capasso L., Raimondi F., Capasso A., Crivaro V., Capasso R., Paludetto R. Early rard clamping protects at-risk neonates from polycythemia. Biol. Neonate. 2003; 83(3): 197-200.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2015 Bionika Media

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies