Transthecal Anesthesia of Fingers



Cite item

Full Text

Abstract

First experience in transthecal anesthesia application for the treatment of 62 patients with different fingers injuries was analyzed. That method showed its efficacy in 52 (83.9%) cases. The level of anesthesia on the palmar surface of the finger corresponded to the injection point, on the dorsal one - to the middle of the main phalanx. Incomplete transthecal block was observed in cases when the injuries or their sequelae resulted in disturbance of tendon sheath leak-proofness (or permeability) as well as in interventions on a thumb.

References

  1. Кузин М.И., Харнас С.Ш. Местное обезболивание. - М., 1982.
  2. Castellenos J., Ramires C., De Sena L., Bertran C. Trans-thecal digital block: digital anasthesia through the sheath of the flexor tendon //J. Bone Jt Surg. - 2000. - Vol. 82B, N 6. - P. 889.
  3. Chevaleraud E., Ragot J.M., Brunelle E. et al. Local anesthesia of the finger through the flexor tendon sheath // Ann. Fr. Anesth. Reanim. - 1993. - Vol.1 2, N 3. - P. 237-240.
  4. Chui D.T.W. Transthecal digital block: flexor tendon sheath used for anesthetic infusion //J. Hand Surg. - 1990. - Vol. 15A, N 3. - P. 471-473.
  5. Cumming A.J., Tosol W.B., Meyer L.E. Modified thansthecal digital block versus traditional digital block for anesthesia of finger //J. Hand Surg. - 2004. - Vol. 29A, N 1. - P. 44-48.
  6. Denghani M., Mahmoodian A. A revisit of transthecal digital block and traditional digital block for anesthesia of figer //J. Rec. Med. Sci. - 2007. - Vol. 12, N 6. - P. 298-300.
  7. Hung V.S., Bodavula V.R.R., Dubin N.H. Digital anasthesia: comparison of the efficacy and pain assosietaed with three digital nerve block techniques //J. Hand Surg. - 2005. - Vol. 30B, N 6. - P. 581-584.
  8. Sarhady N.S., Shaw-Dunn J. Transthecal digital block //J. Hand Surg. - 1998. - Vol. 23B, N 4. - P. 490-493.
  9. Yin Z.G., Zhang J.B., Ran S.L., Wang P. A comparison of traditional digital blocks and single subcutaneus palmar injection blocks at the base of finger and meta-analysis of the digital block trials //J. Hand Surg. - 2006. - Vol. 31B, N 5. - P. 547-554.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2009 Eco-Vector



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77-76249 от 19.07.2019.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies