An improvement of experimental model for a study of local hemostatic agents’ effectiveness

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

With the help of tests on 10 big biological objects (sheep) was studied a modern model of severe lateral damage (6 mm diameter) of femoral artery. Within 45 seconds blood loss was 432,5±258,2 ml. The usage of domestic local hemostatic agent - «Gemostop» based on zeolite and «Gemofleks» based on chitosan. The total three-hour mortality was 50%. Primary hemostasis was recorded only in 20% of biological objects, the final hemostasis in 60%. Thus, the model of standard 6-mm lateral damage of femoral artery with a free primary hemmorage during 45 seconds should be considered as optimal for evaluating the effectiveness of modern hemostatic agents.

全文:

受限制的访问

参考

  1. Бояринцев В.В., Юдин А.Б., Назаров В.Б. и др. Доклиническая оценка эффективности местных гемостатических препаратов (экспериментальное исследование) // Медицина катастроф. - 2010. - № 3 (71). - С. 23-25.
  2. Головко К.П. Особенности оказания медицинской помощи раненым в районе боевых действий и пути ее совершенствования: Дис.. канд. мед. наук. - СПб, 2004. - 209 с.
  3. Денисенко В.В. Роль и место тактики многоэтапного хирургического лечения раненых на этапах медицинской эвакуации: Дис.. канд. мед. наук. - СПб, 2010. - 142 с.
  4. Дмитриев В.А. Применение современных местных гемостатических средств при тяжелых повреждениях печени в системе многоэтапной хирургической тактики («Damage control») при политравме (клинико-экспериментальное исследование): Дис.. канд. мед. наук. - СПб, 2013. - 121 с.
  5. Мирошниченко А.Г., Семкичев В.А., Марусанов В.Е. Малообъемная реанимация: влияние на гемодинамику и гемостаз при травматическом шоке // Скорая медицинская помощь. - 2010. - Т. 11, № 3. - С. 42-48.
  6. Рева В.А. Обоснование системы временной остановки наружного кровотечения при ранениях магистральных сосудов конечностей на догоспитальном этапе: Дис.. канд. мед. наук. - СПб, 2011. - 237 с.
  7. Самохвалов И.М., Головко К.П., Рева В.А. и др. Применение местного гемостатического средства «Celox» в экспериментальной модели массивного смешанного наружного кровотечения // Вестн. Рос. воен.-мед. акад. - 2013. - № 4 (44). - С. 187-191.
  8. Arnaud F., Parreno-Sadalan D., Tomori T. et al. Comparison of 10 hemostatic dressings in a groin transection model in swine // J. Trauma. - 2009. - Vol. 67, N 4. - P. 848-855.
  9. Arnaud F., Teranishi K., Okada T. et al. Comparison of Combat Gauze and TraumaStat in two severe groin injury models // J. Surg. Res. - 2011. - Vol. 169, N 1. - P. 92-98.
  10. Butler F.K., Holcomb J.B., Schreiber M.A. et al. Fluid resuscitation for hemorrhagic shock in Tactical Combat Casualty Care: TCCC Guidelines // J. Spec. Oper. Med. - 2014. - Vol. 14, N 3. - P. 13-38.
  11. Eastridge B.J., Mabry R.L., Seguin P. et al. Death on the battlefield (2001-2011): implications for the future of combat casualty care // J. Trauma Acute Care Surg. - 2012. - Vol. 73, N 6 (Suppl. 5). - P. S431-S437.
  12. Kheirabadi B.S., Arnaud F., McCarron R. et al. Development of a standard swine hemorrhage model for efficacy assessment of topical hemostatic agents // J. Trauma. - 2011. - Vol. 71 (Suppl. 1). - P. S139-S146.
  13. Littlejohn L.F., Devlin J.J., Kircher S.S. et al. Comparison of Celox-A, ChitoFlex, WoundStat, and combat gauze hemostatic agents versus standard gauze dressing in control of hemorrhage in a swine model of penetrating trauma // Acad. Emerg. Med. - 2011. - Vol. 18, N 4. - P. 340-350.

补充文件

附件文件
动作
1. JATS XML

版权所有 © Samokhvalov I.M., Reva V.A., Denisov A.V., Golovko K.P., Sokhranov M.V., Telitskii S.Y., Yudin A.B., 2015



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: № 01975 от 30.12.1992.
##common.cookie##