PRIMARY ENDOPROSTHETIC REPLACEMENT OF THE HIP JOINT USING TRABECULAR TANTALUM TROCHANTERIC COMPONENTS


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Abstract

The paper presents the results of total endoprosthesic replacement of the hip joint using trabecular tantalum trochanteric components. The study is based on 358 operations performed in 2008-2012. The authors consider indications for surgery; the surgical results are traced over 5 years; there is no case of instability of the cup of a tantalum-coated endoprosthesis.

Full Text

Restricted Access

About the authors

V. Murylev

Moscow City Center for Endoprosthetic Replacement of Bones and Joints, S.P. Botkin City Clinical Hospital; I.M. Sechenov First Moscow State Medical University

M. Kholodayev

Moscow City Center for Endoprosthetic Replacement of Bones and Joints, S.P. Botkin City Clinical Hospital

G. Rubin

Moscow City Center for Endoprosthetic Replacement of Bones and Joints, S.P. Botkin City Clinical Hospital

Email: RGG83@mail.ru

Ya. Rukin

I.M. Sechenov First Moscow State Medical University

P. Elizarov

I.M. Sechenov First Moscow State Medical University

References

  1. Мурылев В.Ю., Терентьев Д.И., Елизаров П.М. и др. Тотальное эндопротезирование тазобедренного сустава с использованием танталовых конструкций // Вестн. травматол. и ортопедии им. Н.Н. Приорова. - 2012; 1: 24-9.
  2. Bobyn J., Hacking S., Chan S. et al. Characterization of new porous tantalum biomaterial for reconstructive orthopaedics. Scientific Exhibition: 66th Annual Meeting of the American Academy of Orthopaedic Surgeons, 1999. Anaheim, CA.
  3. Karageorgiou V., Kaplan D. Porosity of biomaterial scaffolds and osteogenesis // Biomaterials. - 2005; 26: 5474-91.
  4. Black J. Biological performance of tantalum // Clin. Materials. - 1994; 16: 167-73.
  5. Lewallen D., Hanssen A., et al. Bone remodeling around porous metal cementlessacetabular components // J Arthroplasty. - 2009; 04: 25.
  6. Unger A., Lewis R., Gruen T. Evaluation of a porous tantalum uncementedacetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips // J. Arthroplasty. - 2005; 20: 1002.
  7. Levine B., Dela Valle C., Jacobs J. Applications of porous tantalum in total hip arthroplasty // J. Am. Acad. Orthop. Surg. - 2006; 14: 646.
  8. Bobyn J., Pillar R., Cameron H. et al. The optimum pore size for the fixation of porous surfaced metal implants by the ingrowth on bone // Clin. Orthop. Relat. Res. - 1980; 150: 263.
  9. Kurtz S., Ong K., Lau E. et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030 // Bone Joint Surg. Am. - 2007; 89 (4): 780-5. doi: 10.2106/JBJS.F.00222.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2013 Russkiy Vrach Publishing House

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies