REGIDRATATsIONNAYa TERAPIYa I VOZMOZhNOSTI EE KONTROLYa U PATsIENTOV S DIABETIChESKIMI KOMAMI (OBZOR LITERATURY)


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Abstract

The methods for optimizing the treatment and control of the results of therapy in patients with impaired bodies of water in any diseases, including diabetic coma, are discussed. The impedance spectroscopy allows to simply and reliably control the dynamics of change in water sector of body at early period of the disease, and should be considered as the basis for recommendations for pathogenetically substantiated infusion-transfusion therapy. At the same time, further studies to assess the clinical importance of bioimpedance analysis in diabetic patients with diabetic coma are necessary.

Full Text

Restricted Access

About the authors

A. V Legun

M. S Vetsheva

References

  1. Александрович Г.А., Маркова А.С., Морозова Н.Н. и др. Диабетические комы. Методические рекомендации для врачей и интернов. С., 2005:3-24.
  2. Балаболкин М.И. Диабетология. М., 2000:590-633.
  3. Баталова Э.Ф. Неинвазивный биоимпедансный метод мониторинга отека головного мозга у больных с тяжелой черепно-мозговой травмой. Дисс. канд. мед. наук. М., 2008. 27 с.
  4. Булатов Р.Д. Применение интегральной двухчастотной импедансометрии в клиническом мониторинге больных с деструктивным панкреатитом // Анест. и реаним. 2012;3:59-62.
  5. Гельфанд Б.Р., Салтанова А.И. Национальное руководство. Интенсивная терапия. М., 2008. С. 911-33.
  6. Демидова И.Ю. Кетоацидоз и кетоацидотическая кома // Клиническая и лабораторная диагностика. 1997. № 9. С. 25-32.
  7. Джон Дж. Марини, Артур П.Уилер, Медицина критических состояний. Эндокринные критические состояния. М., 2002. С. 797-818.
  8. Иванов Г. Г., Сыркин А. Л., Дворников В.Е., Николаев Д.И., Остапченко Д.А., Котлярова Л.В., Байрак И.В. Мультичастотный сегментарный биоимпедансный анализ в оценке изменений объема водных секторов организма. М., 2002. С. 54-87.
  9. Касаткина Э.П. Сахарный диабет у детей и подростков. М., 1996. 239 с.
  10. Малышев В.Д, Андрюхин И.М., Бакушин В.С. и др. Гемогидродинамический мониторинг при интенсивном лечении больных с тяжелым течением перитонита // Анест. и реаним. 1997. № 3. С. 68-72.
  11. Малышев В.Д. Интенсивная терапия. М., 2002. С.347-53.
  12. Малышева В.Д. Интенсивная терапия. Реанимация. Первая помощь. Учебное пособие. М., 2000. 464 с.
  13. Мельниченко Г.А., Удовиченко О.В., Майоров А.Ю. Практическая эндокринология. М., 2002. С. 195-309.
  14. Николаев Д.В., Смирнов А.В., Бобринская И.Г. и др. Биоимпедансный анализ состава тела человека. М., 2009. 400 с.
  15. Симонова А.Ю., Путанова Н.Н., Курилкин Ю.А.
  16. Старкова Н.Е. Клиническая эндокринология. М., 1973. C. 24-76.
  17. Старостина Е.Г. Острая декомпенсация обмена веществ при сахарном диабете // Новый медицинский журнал 1997. № 3. С. 22-8.
  18. Тестов А.Л. Биотехническая система оценки количества жидкости в организме и распределения ее по секторам в реальном времени. Томск, 2004. 136 с.
  19. Тинтиналли Дж.Э., Кроума Рл., Руиза Э. Неотложная медицинская помощь. Пер. с англ. Кандрора В.И., Неверовой М.В., Сучкова А.В., Низового А.В., Амченкова Ю.Л. /Под ред. В.Т. Ивашкина, П.Г. Брюсова. М., 2001. С. 183-245.
  20. Шалимов А.А., Пекарский Д.Е., Чижик О.П. Терапия нарушений водно-солевого равновесия. Киев, 1970. 92 с.
  21. Albert S.N. Blood volume and extracellular fluid volume. Springfield, Illinois: Charles and Thomas Publisher. 1971;15:56-98.
  22. Bracco D, Revelly J, Berger M, et al. Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedance. Crit. Care Med. 1988;26:1065-70.
  23. Chumlea WC, Guo SS, Cockram DB, et al. Mechanical and physiologic modifters and bioelectrical impedance spectrum determinants of body composition. Am. J. Clin. Nutr. 1996;64(Suppl. 3):413S-22S.
  24. De-Lorennzo A, Deurenberg P, Andreoli A, et al. Multifrequency impedance in the assessment of body water losses during dialysis. Renal Physiol. Biochem. 1994;17:326-32.
  25. Fuller HD. The electrical impedance of plasma: a laboratory simulation of the effect of changes in chemistry. Ann. Biomed. Eng. 1991; 19:123-29.
  26. Gagnon RT, Gagner M., Duplessis S. Variations of body comparision by bioelectric impedancemetry after major surgery. Ann. Chir. 1994;48:708-16.
  27. Hannan WJ, Cowen SJ, Plester CE, et al. Comparison of bioimpedance spectroscopy and multi-frequance bioimpedance analysis for the assessment of extracelular and total body water in surgical patients. Clin. Sci. 1995;89: 1651-58.
  28. Hannan WJ, Cowen SJ, Pearon KC, et al. Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin. Sci. Colch. 1994;86:479-85.
  29. Kong CH, Thompson CM, Lewis CA, et al. Determination of total body water in uraemic patients by bioelectrical impedance. Nephrol. Dial. Transplant. 1993;8:716-19.
  30. Kreymann G, Paplow N, Muller C, et al. Relation of total body reactance to resistance as a predictor of mortality in septic patients. Crit. Care Med. 1995;23(Suppl):A49.
  31. Kyle UG, Bosaeus I, De lorenzo AD, et al. Bioelectrical impedance. I. Review of principles and methods. Clin. Nutr. 2004;23:1226-43.
  32. McDonald JJ, Chanduvi B, Velarde G, et al. Bioimpedance monitoring of cholera. Lancet. 1993;341:1049-51.
  33. Patel R, Peterson E, Silverman N, et al. Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Crit. Care Med. 1996;24:1820-28.
  34. Piccoli A, Pillon L, Favaro E. Asymmetry of the total body water prediction bias using the index. Nutrition. 1997;13:438-41.
  35. Rallison LR, Kushner RF, Penn D, et al. Errors in estimating peritoneal fluid by bioelectrical impedance analysis and total body electrical conductivity. J Am Coll Nutr 1993;12:66-72.
  36. Segal KR, Gutin B, Presta E, et al. Estimation of human body composition by electrical impedance methods: a comparative study. J Appl Physiol 1985;58:1565-71.
  37. Tompson CM, Kong CH, Lewis CA, et al. Can bioelectrical impedance be used to measure total body water in dialysis patients? Physiol Meas 1993;14:455-61.
  38. Van Loan MD, Mayclin PL. Use of multi-frequency bioelectrical impedance analysis for the estimation of extracellular fluid. Eur J Clin Nutr 1992;46:117-24.
  39. Woodrow G, Oldroyd B, Smith MA, et al. Measurement of body composition in chronic renal failure: comparison of skinfold anthropometry and bioelectrical impedance with dual energy X-ray absorptiometry. Eur J Clin Nutr 1996;50:295-301.

Supplementary files

Supplementary Files
Action
1. JATS XML

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies