Background: Hydrogen peroxide is widely used as a hemostatic and antiseptic agent. Anecdotal reports also highlight the potential benefits of oral administration of hydrogen peroxide solutions, extending their use beyond oral disinfection. However, the contact with peroxides often overlooks the risk of corrosion damage to artificial dentures, particularly those manufactured 20–30 years ago. At that time, steel alloys were commonly used in denture manufacturing, especially in developing countries such as Vietnam.

AIM: To assess the corrosion risk of dental metals when exposed to medical hydrogen peroxide agents recommended for mouth rinsing and oral administration.

METHODS: The study investigated the corrosion behavior of two dental alloys, an iron alloy and a filling material, in an antiseptic oral solution with 3% w/w hydrogen peroxide (Н2О2) as an active component. The mass corrosion rate was gravimetrically measured for three samples of metal alloys and a filling material in a dental solution. The oxygen release kinetics and solution pH were determined.

RESULTS: In an open-air environment, the hydrogen peroxide solution decomposes intensively to yield oxygen. The time for intensive decomposition of hydrogen peroxide in the test concentration was approximately 500 s, and therefore the chemical and corrosive activity was limited by this interval. Titanium, cobalt and chromium alloys showed high corrosion resistance in the hydrogen peroxide solution. Non-metallic glass-ionomer cements were resistant to the hydrogen peroxide solution. In contrast, iron alloys have high corrosion rates in the hydrogen peroxide medium. Iron alloys corrosion rates and hydrogen peroxide decomposition rates were demonstrated to follow similar temporal patterns. This suggested that oxygen released during hydrogen peroxide decomposition plays a leading role in the corrosion process.

CONCLUSION: Based on the study findings, titanium, cobalt, and chromium alloys and non-metallic glass-ionomer cements demonstrate high corrosion resistance in hydrogen peroxide solutions. The study also highlights that regular use of antiseptic medical solutions containing 3% hydrogen peroxide requires careful consideration of the potential risks posed by their corrosive effects on denture alloys that contain iron components.

全文:

受限制的访问

作者简介

Aleksandra S. Guzenkova

A.N. Severtsov Institute of Ecology and Evolution Problems of the Russian Academy of Sciences; Joint Russian-Vietnamese Tropical Research and Technology Center

编辑信件的主要联系方式.
Email: guzenkova69@gmail.com
ORCID iD: 0000-0002-3277-847X
SPIN 代码: 3487-2737
Scopus 作者 ID: 6506338514
Researcher ID: C-7670-2015

Cand. Sci. (Technical Sciences)

俄罗斯联邦, 33, Leninsky Prospekt, Moscow, 119071; Hanoi, Vietnam

Doan Quy Hieu

Joint Russian-Vietnamese Tropical Research and Technology Center

Email: dqhieu57@gmail.com
ORCID iD: 0000-0002-9555-6970

Cand. Sci. (Technical Sciences)

越南, Hanoi, Vietnam

Sergei A. Guzenkov

A.N. Severtsov Institute of Ecology and Evolution Problems of the Russian Academy of Sciences; Joint Russian-Vietnamese Tropical Research and Technology Center

Email: evgeniiaguzenkova05@gmail.com
ORCID iD: 0000-0001-6632-1702
SPIN 代码: 4153-6121
Scopus 作者 ID: 6602359189
Researcher ID: AAD-8416-2022

Cand. Sci. (Technical Sciences)

俄罗斯联邦, 33, Leninsky Prospekt, Moscow, 119071; Hanoi, Vietnam

Sergei V. Belsky

A.N. Severtsov Institute of Ecology and Evolution Problems of the Russian Academy of Sciences; Joint Russian-Vietnamese Tropical Research and Technology Center

Email: bsv1535538@mail.ru
ORCID iD: 0009-0004-6796-0919

Bachelor (Technical Sciences)

俄罗斯联邦, 33, Leninsky Prospekt, Moscow, 119071; Hanoi, Vietnam

参考

  1. Shestopalov NV, Panteleeva LG, Sokolova NF, et al. Federal clinical guidelines for the selection of chemical disinfectants and sterilizers for use in medical organizations. M.: Remedium Privolzh’e; 2015. 67 p. EDN: TYTFUR
  2. Marshall MV, Cancro LP, Fischman SL. Hydrogen Peroxide: A Review of Its Use in Dentistry. J Periodontol. 1995;66(9):786–796. doi: 10.1902/jop.1995.66.9.786
  3. Kremer ML. The Fenton reaction. Dependence of the rate on pH. J Phys Chem A. 2003;107:1734–1741. doi: 10.1021/jp020654p
  4. Guzenkova AS, Artamonova IV, Guzenkov SA, Ivanov SS. Features of Corrosive Breakdown of Pipe Steel in Gas Condensate. Metallurgist. 2023;67(7–8):1187–1191. doi: 10.1007/s11015-023-01610-4 EDN: QDZAHO
  5. Tredwin CJ, Naik S, Lewis NJ, Scully C. Hydrogen peroxide tooth-whitening (bleaching) products: review of adverse effects and safety issues. Br Dent J. 2006;200(7):371–376. doi: 10.1038/sj.bdj.4813423
  6. Uhlig HH, Winston Revie R. Corrosion and corrosion control. An introduction to corrosion science and engineering. 3rd ed. NY: John Wiley & sons; 1985. 441 p.
  7. Abdurakhmanov AI, Kurbanov OR. Materials and technologies in orthopedic dentistry: textbook. 2nd ed. Moscow: Meditsina; 2008. 288 p. (In Russ.) ISBN 5-225-04361-5 Text: electronic // Electronic Library System “Student Consultant”: [website]. Available from: https://www.studentlibrary.ru/book/ISBN5225043615.html (date accessed: 03/22/2025). Access mode: by subscription.
  8. ISO 9917-1 Glass polyalkenate cement, Luting material. Available from: https://www.gc.dental/europe/sites/europe.gc.dental/files/products/downloads/fuji1/ifu/IFU_Fuji_I_Powder-Liquid_E.pdf (accessed 18.03.2025).
  9. Titley KC, Torneck CD, Smith DC, Applebaum NB. Adhesion of a glass ionomer cement to bleached and unbleached bovire dentin. Endod Dent Traumatol. 1989;5(3):132–138. doi: 10.1111/j.1600-9657.1989.tb00349.x

补充文件

附件文件
动作
1. JATS XML
2. Fig. 1. Change in pH of peroxide solution over time.

下载 (52KB)
3. Fig. 2. Change in the volume of released oxygen depending on time.

下载 (74KB)
4. Fig. 3. Changes in the mass index of corrosion of dental materials over time.

下载 (118KB)
5. Fig. 4. Corrosion products on steel 3 after 5 min of exposure to hydrogen peroxide solution (left) and after 40 min (right), magnification ×60.

下载 (87KB)
6. Fig. 5. Surface of cobalt-chromium alloy after 40 min of exposure in a peroxide-containing medium, magnification ×60.