Complex research of the functional status of fetal in labour

Cover Page


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Abstract

The review presents recent data on assessment of the functional status of fetal in labour, disadvantages of the methods and benefits their integrated use.

Full Text

Restricted Access

About the authors

Sergey Georgievich Kucherjavyy

D. O. Ott Research Institute of Obstetrics and Gynecology

Email: baikal18@yandex.ru
health doctor of maternity ward

References

  1. Абрамченко В. В. Пути снижения абдоминального родоразрешения. Журнал акушерства и женских болезней. 2000; 2: 69-74.
  2. Айламазян Э. К. Кесарево сечение. Общие проблемы и региональные особенности. Журнал акушерства и женских болезней. 2005; 4: 3-10.
  3. Барашнев Ю. И. Клинико-морфологическая характеристика церебральных расстройств при гипоксически-ишемических энцефалопатиях. Акуш. и гин. 2000; 5: 39-42.
  4. Барашнев Ю. И., Бессонова Ю. В. Индикаторы перинатальных повреждений головного мозга плода и новорожденного. Акуш. и гин.1997; 2: 28-33.
  5. Гармашева Н. Л. Патофизиология внутриутробного развития. Л.: Медгиз;1958.
  6. Греннер Д., Марри Р., Мейес П., Родуэл Д. Биохимия человека. Т. 1. М.: МИР. 2002.
  7. Иванова И. А., Бобков Ю. Г. Сравнительное изучение некоторых препаратов на разных моделях гипоксии мозга. Бюлл. эксп. биол. и медицины. 1984; 98 (11): 567-570.
  8. Kесарево сечение в современном акушерстве: методическое письмо. М., 2011.
  9. Кулаков В. И., Чернуха Л. М., Комиссарова Л. М. Кесарево сечение. 2-е изд. М.: Триада-Х. 2004.
  10. Курцер М. А. Организационные аспекты снижения перинатальной заболеваемости и смертности. Вестник Российской Ассоциации акушеров гинекологов. 1999; 4: 42-5.
  11. Леонова Е. В. Гипоксия (патофизиологические аспекты): метод. рекомендации. Висмонт - Мн.: БГМУ. 2002.
  12. Медведев М. В., Юдина Е. В. Задержка внутриутробного развития плода. 2-е изд. М.: РАВУЗДПГ. 1998.
  13. Михайлов А., Тунелл Р. Клиническое руководство по асфиксии плода и новорожденного. СПб. 2001.
  14. Оден М. Кесарево сечение: безопасный выход или угроза будущему? 2-е изд. М. 2009.
  15. Павлова Н. Г., Константинова Н. Н. Неврология плода - возможности и перспективы исследования. Журнал акушерства и женских болезней. 2003; 3 (2): 86-94.
  16. Персианинов Л. С. Дыхательная функция крови плода в акушерской клинике. М.: Медицина; 1971.
  17. Савельева Г. М. Реанимация новорожденных. М.: Медицина. 1973.
  18. Савельева Г. М., Курцер М. А. Значение внедрения новых технологии в развитии перинатальной медицины. Тезисы Всероссийского пленума Ассоциации акушеров и гинекологов. М. 2000: 183-85.
  19. Стрижаков А. Н., Бунин А. Т., Медведев М. В. Антенатальная кардиология. М. 1991.
  20. Стрижаков А. Н., Кузьмина Т. Е. Беременность после кесарева сечения: течение, осложнения, исходы. Вопр. гинекологии, акушерства и перинатологии. 2002; 2: 40-46.
  21. ФГБУ «Центральный научно-исследовательский институт организации и информатизации здравоохранения» Министерства здравоохранения Российской Федераци. URL: www.mednet.ru/ru/statistika.html. - (дата обращения 15.10.2014).
  22. Чернуха Е. А. Родовой блок. М.: Медицина. 2005.
  23. Шабалов Н. П. Асфиксия новорожденных М.: Медпресс-информ. 2003.
  24. Шевченко Ю. Л. Гипоксия. Адаптация, патогенез, клиника. СПБ. 2000.
  25. Alfirevic Z., Devane D., Gyte G. M. L. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database of Systematic Reviews. 2006; 3: CD006066.
  26. Amer-Wahlin I., Ingemarsson I., Marsal K., Herbst A. Fetal heart rate patterns and ECG ST Segment changes preceding metabolic acidaemia at birth. BJOG.2005;112: 160-5.
  27. Amer-Wahlin I., Hellsten C., Noren H. et al. Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial. Lancet. 2001; 358: 534-38.
  28. Bloom S. L., Spong C. Y., Thom E. et al. Fetal pulse oximetry and cesarean delivery. N. Engl. J. Med. 2006; 355 (21): 2195-2202.
  29. Bretscher J., Sailing E. pH values in the human fetus during labour. Am. J. Obst. Gynecol. 1967; 97: 906-11.
  30. Carbonne B. Langer B. Goffinet F. et al. Multicenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry. Am. J. Obstet. Gynecol. 1997; 177: 593-98.
  31. Carbonne B., Nguyen F. Fetal scalp blood sampling for pH and lactate measurement during labour. J. Gynecol. Obstet. Biol. Reprod. 2008; 37 (Suppl. 1): S65-S71.
  32. Conev A., Marshall J. M. Effect of systemic hypoxia uponcirculation of the cerebral cortex in the anaesthetized rat. J. Phisiol. Proc. 1995; 483: 88.
  33. Dildy G. A., Clark S. L., Loucks C. A. Preliminary experience with intrapartum fetal pulse oximetry in humans. Obstet. Gynecol. 1993; 81: 630-35.
  34. East C. E., Brennecke S. P., King J. F. et al. The effect of intrapartum fetal pulse oximetry, in the presence of a nonreassuring fetal heart rate pattern, on operative delivery rates: a multicenter, randomized, controlled trial (the FOREMOST trial). Am. J. Obstet. Gynecol. 2006;194 (3): 606-16.
  35. Freeman R. K., Garite T. J., Nageotte M. P., Miller L. A. Fetal heart rate monitoring. 4th ed. N. Y.; 2012.
  36. Flamm B. L. Vaginal birth after caesarean (VBAC) - Best Practice A Research Clinic. Obstet. Gynecol. 2001; 15 (1): 21-92.
  37. Gardosi J. O., Damianou D., Schram C. M. H. Artifacts in fetal pulse oximetry: Incomplete sensor-to-skin contact. Am. J. Obstet. Gynecol. 1994; 14: 11-13
  38. Gardosi J., Reed N., Sahota B. Fetal pulse oximetry with the balloon probe. In Knitza R, ed. Hypoxische Gefahrdung des Fetus Sub Partu. Darmstadt: Steinkopff.1994: 179-83
  39. Gardosi J. O., Schram C. M., Symonds E. M. Adaptation of pulse oximetry for fetal monitoring during labor. Lancet. 1991; 337: 1265-67.
  40. Garite T. J., Dildy G. A., McNamara H. et al. A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns. Am. J. Obstet. Gynecol. 2000;183 (5):1049-58.
  41. Goodwin T. M., Milner-Masterson L., Paul R. H. Elimination of fetal scalp blood sampling on a large clinical service. Obstet. Gynecol. 1994; 83: 971-74.
  42. Johnson N. The development and potential of fetal pulse oximetry. Contemp. Rev. Obstet. Gynecol. 1991; 3: 1-12.
  43. Johnson N., Johnson V., Fisher J. et al. Fetal monitoring with pulse oximetry. Br. J. Obstet. Gynaecol. 1991; 98: 36-41
  44. Intrapartum fetal heart rate monitoring: nomenclature, interpretation, and general management principles: American College of Obstetricians and Gynecologists. ACOG Practice Bulletin No. 106. Obstet. Gynecol. 2009; 114 (1): 192-202.
  45. Kazandi M., Sendag F., Akercan F. Different types of variable deceleration and their effects to neonatal outcome. Singapore Med. J. 2003; 44 (5): 243-47.
  46. Klauser C. K., Christensen E. E., Chauhan S. P. et al. Use of fetal pulse oximetry among high-risk women in labor: a randomized clinical trial. Am. J. Obstet. Gynecol. 2005;192 (6): 1810-17.
  47. Kuhnert M., Seelbach-Goebel B., Butterwegge M. Predictive agreement between the fetal arterial oxygen saturation and fetal scalp pH: Results of the German multicenter study. Am. J. Obstet. Gynecol. 1998; 178: 330-35.
  48. Kuhnert M., Schmidt S. Intrapartum management of nonreassuring fetal heart rate patterns: a randomized controlled trial of fetal pulse oximetry. Am. J. Obstet. Gynecol. 2004; 191 (6): 1989-95.
  49. Liston R., Sawchuck D., Young D. Fetal health surveillance: antepartum and intrapartum consensus guideline.Society of Obstetrics and Gynaecologists of Canada; British Columbia Perinatal Health Program. J. Obstet. Gynaecol. Can. 2007; 29 (suppl. 4): S3-56.
  50. Luttkus A., Fengler T. W., Friedmann W. et al: Continuous monitoring of F-SpO2 by pulse oximetry. Obstet. Gynecol. 1995; 85: 183-86.
  51. Martin A. Fetal heart rate during labour: definitions and interpretation. J. Gynecol. Obstet. Biol. Reprod. 2008; 37 (suppl. 1): S34-S45.
  52. Macones G. A., Hankins G. D., Spong C. Y., Hauth J., Moore T. The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. Obstet. Gynecol. 2008; 112: 661-66.
  53. McNamara H., Chung D. C., Lilford R. et al. Do fetal pulse oximetry readings at delivery correlate with cord blood oxygenation and acidemia? Br. J. Obstet. Gynaecol. 1992; 99: 735-38.
  54. National Institute of Child Health and Human Development Research Planning Workshop. Electronic Fetal Heart Rate Monitoring: Research Guidelines for Interpretation. Am. J. Obstet. Gynecol. 1997; 177: 1385-90.
  55. National Institute for Clinical Excellence. Royal College of Obstetricians and Gynecologists. The use of electronic fetal heart rate monitoring. Evidence Based Clinical Guidline N. 8. London: RCOG Press, 2001.
  56. Nellcor Puritan Bennett. Technical Issue of Nonivasive Fetal Oxygen Saturation Monitoring Using the Nelcor N-400. Pleasanton: Nellcor Puritan Bennet; 1995.
  57. Nordstroem L. Fetal scalp and cord blood lactate. Best Pract. Res. Clin. Obst. Gynecol. 2004; 18 (3): 467-76.
  58. Ojala K., Vaarasmaki M., Makikallio K., Valkama M., Tekay A. A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography - a randomised controlled study. BJOG 2006; 113: 419-23.
  59. Raman S., Lim J. M., Hanifullah K., Omar A. The use of intrapartum fetalpulse oximetry in the presence of fetal cardiac arrhythmia due to a cardiac tumour. J. Obstet. Gynaecol. 1999; 19 (2): 200-1.
  60. Ramanah R., Martin A., Rietmueller D. Value of fetal scalp lactate sampling during labour: a comparative study with scalp with scalp pH. Gynecol. Obst. Fertill. 2005; 33 (3): 107-12.
  61. Saling E. A new method for examination of the child during labor. Introduction, technic and principles. Arch. Gynakol. 1962; 197: 108-22.
  62. Shy K. K., Luthy D. A., Bennett F. C. et al. Effects of electronic fetal-heart-rate monitoring, as compared with periodic auscultation, on the neurologic development of premature infants. N. Engl. J. Med. 1990; 322 (9): 588-93.
  63. Smith R. P. Transcutaneous oximetry in obstetrics and gynecology. Obstet. Gynecol. Surv. 1990; 45: 819-957.
  64. ST analysis of the fetal ECG as an adjunct to fetal heart rate monitoring in labour - a clinical validation. Department of Obstetrics and Gynecology, Perinatal Center, Sahlgrenska University Hospital. Gothenburg; 2008
  65. Taylor M. B., Whitwarn J. G. The current status of pulse oximetry. Anaesthesia 1986; 41: 94320.
  66. Tuffnell D., Haw W. L., Wilkinson K. How long does a fetal scalp blood sample take? Br. J. Obst. Gynecol. 2006; 113: 332-34.
  67. Visser G. H. STAN S21 fetal heart monitor for fetal surveillance during labor: an observational study in 637 patients. J. Matern. Fetal. Neonatal. Med. 2004; 15: 400-7.
  68. Evidence based obstetric care URL: http://www.neoventa.com/st-analysis/. - (дата обращения 15.10.2014).
  69. Weissman A., Elchalal U. Fetal oxygen saturation measurement - Present and future. Harefuah. 1992;122: 374-9.
  70. Westerhuis M. E., Kwee A., van Ginkel A. A., Drogtrop A. P., Gyselaers W. J., Visser G. H. Limitations of ST analysis in clinical practice: three cases of intrapartum metabolic acidosis. BJOG. 2007; 114 (10): 1194-201.
  71. Westgate J., Harris M., Curnow J. S., Greene K. R. Plymouth randomized trial of cardiotocogram only versus ST waveform plus cardiotocogram for intrapartum monitoring in 2400 cases. Am. J. Obstet. Gynecol. 1993; 169 (5): 1151-60.
  72. Westgate J., Greene K. How well is fetal blood sampling used in clinical practice? Br. J. Obstet. Gynaecol. 1994;101: 250-51.
  73. Westgate J. A., Wibbens A., Bennet L. et al. The intrapertum deceleration in center stage: a physiologic approach to the interpretation of fetal heart rate changes in labour. Am. Obst. Gynecol. 2007; 197 (3): 1-11.
  74. Yam J., Chua S., Arulkumaran S. Intrapartum fetal pulse oximetry. Part I: Principles and technical issues. Obstet. Gynecol. Surv. 2000; 55 (3):163-72.
  75. Zalar R. W., Quilligan E. J. The influence of scalp sampling on the cesarean section rate for fetal distress. Am. J. Obstet. Gynecol. 1979; 135 (2): 239-46.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2014 Kucherjavyy S.G.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 66759 от 08.08.2016 г. 
СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия Эл № 77 - 6389
от 15.07.2002 г.



This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies