Surgical treatment of Ahmed glaucoma valve’s tube protrusion relapse. Clinical observations

封面


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅或者付费存取

详细

In the practice of an ophthalmic surgeon, patients with a large number of concomitant conditions after repeated surgical interventions are seen with increasingly frequency. One of the grave complications in such patients is secondary glaucoma with a refractory type of course. After successful compensation of intraocular pressure in such patients, the risk of complications increases many times, for example, protrusion of the Ahmed valve drainage tube, which becomes the entrance gate for infection, which can lead to endophthalmitis. This article presents clinical cases of surgical treatment of recurrent protrusion of the Ahmed valve drainage tube.

全文:

受限制的访问

作者简介

Anna Starostina

S. Fyodorov Eye Microsurgery Federal State Institution

Email: anna.mntk@mail.ru
ORCID iD: 0000-0002-4496-0703

MD, Cand. Sci. (Medicine)

俄罗斯联邦, Moscow

Konstantin Burlakov

S. Fyodorov Eye Microsurgery Federal State Institution

编辑信件的主要联系方式.
Email: konstantin.burlakow@yandex.ru
ORCID iD: 0000-0002-4383-0325
俄罗斯联邦, 59a, Beskudnikovskiy boulevard, Moscow, 127486

参考

  1. Kapelushnik N, Singer R, Barkana Y, et al. Surgical outcomes of Ahmed glaucoma valve implantation without plate sutures: a 10-year retrospective study. J Glaucoma. 2021;30(6):502–507. doi: 10.1097/IJG.0000000000001813
  2. Arikan G, Gunenc U. Ahmed glaucoma valve implantation to reduce intraocular pressure: Updated perspectives. Clin Ophthalmol. 2023;17:1833–1845. doi: 10.2147/OPTH.S342721
  3. Patel S, Pasquale LR. Glaucoma drainage devices: a review of the past, present, and future. Semin Ophthalmol. 2010;25(5–6): 265–270. doi: 10.3109/08820538.2010.518840
  4. Yazdani S, Mahboobipour H, Pakravan M, et al. Adjunctive Mitomycin C or amniotic membrane transplantation for Ahmed glaucoma valve implantation: a randomized clinical trial. J Glaucoma. 2016;25(5):415–421. doi: 10.1097/IJG.0000000000000256
  5. Bains U, Hoguet A. Aqueous drainage device erosion: a review of rates, risks, prevention, and repair. Semin Ophthalmol. 2018;33(S1):1–10. doi: 10.1080/08820538.2017.1353805
  6. Chaku M, Netland PA, Ishida K, Rhee DJ. Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery. Clin Ophthalmol. 2016;10:547–553. doi: 10.2147/OPTH.S104029
  7. Coleman AL, Hill R, Wilson MR, et al. Initial clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol. 1995;120(1):23–31. doi: 10.1016/S0002-9394(14)73755-9
  8. Topouzis F, Coleman AL, Choplin N, et al. Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol. 1999;128(2):198–204. doi: 10.1016/S0002-9394(99)00080-X
  9. Yalvac IS, Eksioglu U, Satana B, Duman S. Long-term results of Ahmed glaucoma valve and Molteno implant in neovascular glaucoma. Eye. 2007;21(1):65–70. doi: 10.1038/sj.eye.6702125
  10. Pakravan M, Hatami M, Esfandiari H, et al. Ahmed glaucoma valve implantation: graft-free short tunnel small flap versus scleral patch graft after 1-year follow-up: a randomized clinical trial. Ophthalmol Glaucoma. 2018;1(3):206–212. doi: 10.1016/j.ogla.2018.10.008
  11. Smith MF, Doyle JW, Ticrney JW Jr. A comparison of glaucoma drainage implant tube coverage. J Glaucoma. 2002;11(2):143–147. doi: 10.1097/00061198-200204000-00010
  12. Wigton E, Swanner C, Joiner J, et al. Outcomes of shunt tube coverage with glycerol preserved cornea versus pericardium. J Glaucoma. 2014;23(4):258–261. doi: 10.1097/IJG.0b013e31826a96e8
  13. Panda S, Khurana M, Vijaya L, et al. Comparison of conjunctiva-related complications between scleral and corneal patch grafts in Ahmed glaucoma valve implantation. Indian J Ophthalmol. 2023;71(3):881–887. doi: 10.4103/ijo.IJO_1846_22

补充文件

附件文件
动作
1. JATS XML
2. Fig. 1. Biomicroscopy of the anterior segment of the right eye with recurrent protrusion of the valve drainage tube

下载 (189KB)
3. Fig. 2. Stages of surgical treatment of a patient with recurrent protrusion: a — the tube fixed with interrupted sutures to the sclera, shifted away from the site of the last protrusion; b — the drainage tube is covered by a complex of donor material + tenon capsule and fixed with interrupted sutures; c — the surgical area is covered by conjunctiva

下载 (208KB)
4. Fig. 3. Biomicroscopy of the anterior segment of the eye after the fourth revision of the protrusion of the valve drainage tube

下载 (249KB)
5. Fig. 4. Biomicroscopy of the anterior segment of the left eye with recurrent protrusion of the valve drainage tube

下载 (318KB)
6. Fig. 5. Biomicroscopy of the anterior segment of the left eye on the first day after the revision of the protrusion of the valve drainage tube

下载 (182KB)