Research of physical and mechanical characteristics of suture material in experiment in operations on liver

Cover Page


Cite item

Abstract

Taking into account the peculiarities of the blood supply to the liver and the structure of its parenchyma, and, as a result, considerable difficulties in providing reliable hemostasis without additional traumatization, a surgeon needs to be careful when performing a surgical manipulation. Despite a large number of modern methods for stopping parenchymal bleeding, many practi-tioners give preference to classic methods of hemostasis, including ligation of bleeding vessels in the bulk of the organ using specialized sutures. One of the most serious complications of the use of suture material is cutting of organ tissue, which leads to enhanced bleeding and expansion of the area of damage. At the moment, the tactics of choosing suture material for surgical procedures is empirical. In this context, the aim of this study was to assess the physico-mechanical properties of suture material regarding its structure, and to develop a criterion for choosing surgical sutures for surgical procedures. For the study, the liver was removed out of corpses of males of 35 to 40 years of age, after which separate sections of 7.5×7×4 cm in size were obtained from it. Then a wound 3 cm long and 2 cm deep was made. The wound was sutured with a simple interrupted suture without tightening, but with application of one simple half-node. For suturing, catgut, twisted capron and polyglycolide thread were used. Attention was paid to the maximal force applied at the moment of cutting (Fmax) and the degree of pulling the thread at the moment of cutting (Lu). The analysis of the data was based on comparison of Fmax and Lu parameters. This method permits to refuse from the empirical approach to the choice of suture material for operations on the liver, and to develop a criterion for choosing surgical sutures.

Full Text

 Organ-saving operations present an important problem in modern abdominal surgery [1]. For example, trauma of the liver is one of most severe in the course and most difficult in the diagnosis abdominal damages that makes 30% of traumas of the abdominal organs. Taking into account peculiarities of the blood supply to the liver, its wounds are associated with massive parenchymal bleeding [2-3]. To evaluate the extent of traumatization of the organ, different scales are used. Members of the Department of Operative Surgery and Topographic Anatomy of Kursk State Medical University proposed their own classification of liver damages:

  1. Without breakage of integrity of the capsule;
  2. With breakage of integrity of the capsule;
  3. Damage to the ligamentous apparatus;
  4. Damage to extrahepatic vessels [4].

In treatment of trauma of the liver both conservative and surgical methods are used. Surgical manipulations include ligation of the large hepatic vessels, resection of the damaged part of parenchyma, application of a hemostatic sponge, etc. However, all the described methods imply use of surgical sutures. Among several classification categories of suture materials of highest scientific interest is the structure of threads [5].

There exist two large groups of sutures differing in the texture: monofilament and polyfilament. The latter includes twisted and braided suture material. Of no less importance are such properties of surgical sutures as elasticity and biological inactivity [6-9].

However, in Russian and international scientific literature there is no information about investigation of physico-mechanical characteristics of suture material for use on the biological objects, and tightening of the node is evaluated only subjectively [10-11].

The aim of the study is evaluation of physico-mechanical characteristics of suture material of different structure and elaboration of the criterion for selection of surgical sutures for surgical treatment.

Materials and Methods

The base for the given study was laboratory of experimental surgery and oncology of Research Institute of Experimental Medicine (LESO RIEM) of Kursk State Medical University of Healthcare Ministry of Russia.

The object of study was portions of the diaphragmal surface of the right lobe of the liver of corpses of males 35-40 years old taken in the Office of the Chief Medical Examiner of Kursk. Taking out and use of the biological material were permitted by Regional Ethic Committee within the frames of the RF Government Decree of 21.07.2012 №750 (ed. of 17.12.2016) «On approval of regulations of transfer of non-claimed body, organs and tissues of a dead person for use for medical, scientific and educational purposes and also of use of non-claimed body, organs and tissues of a dead person for the mentioned purposes».

One of the main criteria for selection of the biological material was the absence of any macroscopic pathological alterations, and also the absence of hepatic diseases in history. The time interval between taking out of the organ and its use was not more than 4 hours to minimize the negative influence of autolysis on the reliability of the obtained results.

For examination a part of parenchyma 7.5×7×4 cm in size was separated from the organ. The next step was making a wound on the isolated part of the organ 3 cm long, 2 cm deep. The wound was sutured with simple interrupted stitches without tightening, with application of one simple half-node. For ligation, a piece of suture material was used 50 cm in length. Such length of thread is optimal for further work on the test bed. Monofilament (catgut), twisted (twisted capron) and braided (polyglycolide) suture materials of the same thickness (3/0 by USP) were used. After modeling and ligation of the wound the studied part of the organ was placed on the device for examination of the physico-mechanical characteristics of the sutures and suture material, of the extent of deformation of the parenchyma of the organs (patent №184617). The device was designed on the base of LESO RIEM of Kursk State Medical University [12].

An additional equipment was universal testing electromechanical machine РЭМ–0,2-1 (OOO Metrotrest, Neftekamsk, Republic of Bashkortostan) equipped with a dynamometer and a display showing changes in the pulling of the suture material in the graphic form. Maximal effort (Fmax) applied before cutting of the organ parenchyma and/or rupture of suture material was analyzed, and also the extent of pulling of the thread (Lu). For the study 3 groups of 60 samples in each were formed with different structure of the used suture material. The obtained results were interpreted using methods of statistical processing (calculation of the arithmetic mean, the average error of mean, of 25th and 75th percentiles). Statistical significance of comparisons was determined using Mann-Whitney test with р≤0.05 admissible for biomedical studies. As software for statistical processing, license versions of Statistica programs were used (version 10.0, Stat Soft Inc., USA) and Excel 2013 spreadsheet program (Microsoft Office, USA).

Results and Discussion

According to the results of study (Tables 1, 2), the mean Fmax in use of monofilament suture material at which cutting of parenchyma took place, was 65.20 Н, with the medium pulling of thread 54.31 mm, that was the lowest value in three groups.

 

Table 1 Fmax (Н) Parameters of Studied Groups

Parameter

Suture Material

monofilament

twisted

braided

M

65.20

88.68

78.01

m

0.059

0.64

0.083

Me

65.21

81.24

78.02

25th percentile

65.23

81.34

78.9

75th percentile

65.31

89.93

79.56

р

***≤ 0.05

**≥ 0.05

*≤ 0.05

Note: * – comparison of the mean Fmax values of samples sutured with braided suture material with samples sutured with monofilament threads; ** – comparison of the mean Fmax values of samples sutured with twisted material with samples sutured with braided surgical threads; *** – comparison of mean Fmax values sutured with monofilament material with samples sutures with twisted threads 

 

Table 2 Lu Parameters (mm) of Studied Groups

Parameter

Suture Material

monofilament

twisted

braided

M

54.31

72.75

63.64

m

0.057

0.68

0.1

Me

54.41

72.54

63.77

25th percentile

54.4

71.11

64.36

75th percentile

54.43

74.26

64.83

р

***≤ 0.05

**≥ 0.05

*≤ 0.05

Note: * – comparison of the mean Lu values of samples sutured with braided material with samples sutured with monofilament threads; ** – comparison of mean Lu values of samples sutured with twisted material with samples sutured with braided surgical threads; *** – comparison of mean Lu values of samples sutured with monofilament material with samples sutured with twisted threads

 

The obtained results permit to state that the least preferable suture material in operations on the liver is monofilament. However, there exists practical necessity in the introduction and evaluation of the coefficient that can help standardize and scientifically substantiate selection of suture material for certain kinds of surgical manipulations.

The authors propose to introduce cutting coefficient (Cc) calculated as the ratio of Fmax to Lu (the value that should be ≥1). This is associated with the fact that during tightening of the node the Lu parameter increases while the cross section area of the thread and the area of its contact with the bulk of parenchyma decreases which increases the risk of cutting. Therefore, in operations on the liver the suture material should be used that can withstand high axial load with insignificant stretch.

Conclusion

Thus, the conducted study permitted to identify statistically significant differences between monofilament and twisted/braided suture material and put into a question the reasonability of using monofibers in operations on the liver.

The proposed cutting coefficient will permit to gradually refuse from the empiric approach to selection of suture material.

×

About the authors

Vyacheslav A. Lipatov

Kursk State Medical University,

Email: d.artyom21@gmail.com
ORCID iD: 0000-0001-6121-7412
SPIN-code: 1170-1189
ResearcherId: D-8788-2013

MD, PhD, Professor, Professor of the Department of Operative Surgery and Topographic Anatomy; Head of the Experimental Surgery and Oncology Laboratory of Research Institute of Experimental Medicine

Russian Federation, Kursk

Dmitriy A. Severinov

Kursk State Medical University,

Email: d.artyom21@gmail.com
ORCID iD: 0000-0003-4460-1353
SPIN-code: 1966-0239
ResearcherId: G-4584-2017

Assistant of the Department of Pediatric Surgery and Pediatrics at the Faculty Postgraduate Education

Russian Federation, Kursk

Artem A. Denisov

Kursk State Medical University

Author for correspondence.
Email: d.artyom21@gmail.com
ORCID iD: 0000-0001-5034-8580
SPIN-code: 8500-0129
ResearcherId: AE-1837-2019

Student of the Medical Faculty

Russian Federation, Kursk

Sergey V. Lazarenko

Kursk State Medical University

Email: d.artyom21@gmail.com
ORCID iD: 0000-0002-7200-4508
SPIN-code: 1723-9128
ResearcherId: Y-9451-2018

MD, PhD, Assistant of the Department of Oncology

Russian Federation, Kursk

Nikolay N. Grigor’yev

Kursk State Medical University

Email: d.artyom21@gmail.com
ORCID iD: 0000-0002-4102-1516
SPIN-code: 5476-4857

MD, PhD, Associate Professor, Professor of the Department of Surgical Diseases at the Faculty Postgraduate Education

Russian Federation, Kursk

References

  1. Açan E, Hapa O, Barber FA. Mechanical Properties of Suture Materials. In: Akgun U., Karahan M., Randelli P., et al., editors. Knots in Orthopedic Surgery. Springer, Berlin, Heidelberg; 2017. P. 21-31. doi: 10.1007/978-3-662-56108-9_3
  2. Vinnik YuS, Markelova NM, Shishatskaya ЕI, et al. Immunohistochemical Markers of Local Tissue Response to the Implantation of Products Made from PHA. Journal of Siberian Federal University. Biology. 2016;9(1):109-20. (In Russ). doi:10.17516/ 1997-1389-2015-9-1-109-120
  3. Radojkovic M, Stojkovic M, Golubovic I, et al. The influence of various microenvironmental factors on biomechanical features of different suture materials used in hepato-pancreato-biliary surgery. Facta universitatis. Series: Medicine and Biology. 2019; 21(3):95-100. doi: 10.22190/FUMB190625015R
  4. Severinov DA, Denisov AA, Ananjan TT. Shvy parenhimatoznyh organov: preimushhestva i nedostatki. In: Problemy gemostaza v hirurgii XXI veka; 2017 May 18-19. Kursk; 2017. P. 17-20. Available at: http://conferencinnova.ru/images/hemo2017/hemo 2017.pdf. Accessed: 2019 December 12. (In Russ).
  5. Zhukovskiy VА. Modern suture materials and other fiber implants. Main trend. In: Conference «Biotechnology and quality of life»; 2014 March 18-20. Moscow; 2014. P. 505-506. Available at: http:// www.spsl.nsc.ru/FullText/konfe/bio2014_tezis.pdf. Accessed: 2019 December 12. (In Russ).
  6. Arshakyan VA, Gynter VE, Shtofin SG, et al. Ways of improvement of surgical sutural material. ActaBiomedica Scientifica. 2017;2(6(118)):193-7. (In Russ). doi: 10.12737/article_5a0a910977eca1.04637486
  7. Meyer DC, Bachmann E, Lädermann A, et al. The best knot and suture configurations for high-strength suture material. An in vitro biomechanical study. Orthopaedics & Traumatology, Surgery & Research. 2018;104(8):1277-82. doi: 10.1016/j.otsr. 2018.08.010
  8. Zhang G., Zeng X., Su Y., et al. Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach. Journal of the Mechanical Behavior of Biomedical Materials. 2018;80:171-9. doi:10.1016/ j.jmbbm.2018.02.003
  9. Lazarenko VA, Bobrovskaja EA. Biosovmestimost' v zone «protez – arterija – shovnyj material» s pozicii stenoticheskih okkljuzij posle rekonstruktivno-vosstanovitel'nyh operacij. In: Materials of the International scientific-practical conference «Medical implants»; 2016 March 18-19. Kursk; 2016. P. 71-2. Available at: http://conferencinnova. ru/images/cbooks/Sbornik_materialov_konferentsii_-_Med_ implanty_-_2016.pdf. Accessed: 2019 December 12. (In Russ).
  10. Abellán D, Nart J, Pascual A, et al. Cohen and others. Physical and Mechanical Evaluation of Five Suture Materials on Three Knot Configurations: An in Vitro Study. Polymers. 2016;(8):147. doi:10.3390/ polym8040147
  11. Johnson PC, Roberts AD, Hire JM, et al. The effect of instrumentation on suture tensile strength and knot pullout strength of common suture materials. Journal of Surgical Education. 2016;73(1):162-5. doi: 10.1016/j.jsurg.2015.08.011
  12. Lazarenko VA, Lipatov VA, Lazarenko SV, et al. Ustrojstvo dlja issledovanija fiziko-mehanicheskih harakteristik shvov i shovnogo materiala, stepeni deformacii parenhimy organov. Patent RUS №184617U1. 03.07.2018. Available at: https:// rusneb.ru/catalog/000224_000128_0000184617_20181101_U1_RU/. Accessed: 2019 December 12. (In Russ).

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2020 Lipatov V.A., Severinov D.A., Denisov A.A., Lazarenko S.V., Grigor’yev N.N.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Media Registry Entry of the Federal Service for Supervision of Communications, Information Technology and Mass Communications (Roskomnadzor) PI No. FS77-76803 dated September 24, 2019.



This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies