Comparative assessment of ct-bypass angiography and invasive coronary angiography in patients after coronary bypass surgery in the late postoperative period


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The aim of the study was to evaluate the diagnostic accuracy of ct-bypass angiography in the evaluation of significant stenosis and occlusion of grafts, recipient and nongrafted vessels in patients after coronary bypass surgery in the late postoperative period. Ct-bypass angiography was performed on 64-slice ct scanner with a slice thickness of 0,5 mm and a gantry rotation time of 0,4 s. All results were compared with quantitative invasive coronary angiography. 43 patients with 113 grafts were included in the study. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy for the evaluation of significant stenosis were 94%, 95%, 88%, 98%, 95%, respectively. Diagnostic accuracy for the evaluation of significant stenosis in the recipient and nongrafted vessels were 91% and 90%, respectively. The diagnostic accuracy for the evaluation graft occlusion, recipient and nongrafted vessels was 100%, 100% and 98%, respectively.

Full Text

Restricted Access

References

  1. Бокерия Л.А., Гудкова Р.Г. Сердечнососудистая хирургия — 2010. Болезни и врожденные аномалии системы кровообращения: Практич. рук-во. — М.: НЦССХ им. А.Н. Бакулева РАМН, 2011. - 191 с.
  2. Desbiolles L., Leschka S., Plass A. et al. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT // Eur. Radiol. - 2007. - Vol. 17, N 11. - P. 28192828.
  3. Elhendy A., van Domburg R.T., Bax J.J. et al. Dobutamine-atropine stress myocardial perfusion SPECT imaging in the diagnosis of graft stenosis after coronary artery bypass grafting // J. Nucl. Cardiol. - 1998. - Vol. 5, N 5. - P. 491-497.
  4. Hata M., Yoshitake I., Wakui S. Long-term patency rate for radial artery vs. saphenous vein grafts using same-patient materials // Circ. J. -2011. - Vol. 75, N 6. - P. 1373-1377.
  5. Kawamura M. et al. Patency rate of the internal thoracic artery to the left anterior descending artery bypass is reduced by competitive flow from the concomitant saphenous vein graft in the left coronary artery // Eur. J. Cardiothorac. Surg. - 2008. - Vol. 34, N 4. - P. 833-838.
  6. Khan M.F., Herzog C., Landenberger K. et al.Visualisation of noninvasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography // Eur. Radiol. - 2005. - Vol. 15, N 1. - P. 118-126.
  7. Kuettner A., Trabold T., Schroeder S. et al. Non-invasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results // J. Am. Coll. Cardiol. - 2004. - Vol. 44, N 6. -P. 1230-1237.
  8. Maniar H.S., Sundt T.M., Barner H.B. et al. Effect of target stenosis and location on radial artery graft patency // J. Thorac. Cardiovasc. Surg. - 2002. - Vol. 123, N 1. - P. 45-52.
  9. Meijboom W.B., Meijs M.F., Schuijf J.D. et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study // J. Am. Coll. Cardiol. - 2008. - Vol. 52, N 25. - P. 2135-2144.
  10. Miyakawa A.A., Dallan L., Lacchini S. Human saphenous vein organ culture under controlled hemodynamic conditions // Clinics. -2008. - Vol. 63, N 5. - P. 683-688.
  11. Nazeri I., Shahabi P., Tehrai M. et al. Assessment of patients after coronary artery bypass grafting using 64-slice computed tomography // Am. J. Cardiol. - 2009. - Vol. 103, N 5. - P. 667673.
  12. Salm L.P., Bax J.J., Jukema J.W. et al. Comprehensive assessment of patients after coronary artery bypass grafting by 16-detector-row computed tomography // Am. Heart. J. - 2005. - Vol. 150, N 4. - P. 775-781.
  13. Serruys P.W., Morice M.C., Kappetein A.P. et al. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease // N. Engl. J. Med. - 2009. -Vol. 360, N 10. - P. 961-972.
  14. Stein P.D., Beemath A., Skaf E. et al. Usefulness of 4-, 8-, and 16-slice computed tomography for detection of graft occlusion or patency after coronary artery bypass grafting // Am. J. Cardiol. - 2005. - Vol. 96, N 12. -P. 1669-1673.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2013 Menkov I.A., Trufanov G.E., Zheleznyak I.S., Rud S.D., Knyazev E.A.



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: № 01975 от 30.12.1992.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies