Effect of zonular weakness on refractive outcomes of phacoemulsification
- Authors: Belov D.F.1,2, Potemkin V.V.1,3, Nikolaenko V.P.1,2, Ruziboeva B.O.2
-
Affiliations:
- City Multifield Hospital No. 2
- Saint Petersburg State University
- Academican I.P. Pavlov First St. Petersburg State Medical University
- Issue: Vol 18, No 2 (2025)
- Pages: 43-50
- Section: Original study articles
- Submitted: 09.01.2025
- Accepted: 30.04.2025
- Published: 18.07.2025
- URL: https://journals.eco-vector.com/ov/article/view/645365
- DOI: https://doi.org/10.17816/OV645365
- EDN: https://elibrary.ru/NFSNIN
- ID: 645365
Cite item
Abstract
BACKGROUND: Zonular weakness caused by pseudoexfoliative syndrome is very common among residents of Northwest Russia. Along with the increasing risk of intraoperative complications, zonular weakness may worsen refractive outcomes of phacoemulsification, as it affects the effective lens position.
AIM: The work aimed to assess the effect of zonular weakness on refractive outcomes of phacoemulsification.
METHODS: The study included data from 282 patients (282 eyes) divided into the following three groups: patients with healthy zonules (n=109; group 1, control), patients with pseudoexfoliative syndrome (n=100; group 2), and patients with grade I lens subluxation caused by pseudoexfoliative syndrome and required capsular tension ring implantation (n=73; group 3). Intraocular lens power was calculated using the SRK/T formula. Optical biometry was performed using IOL-Master 500 device (Carl Zeiss, Germany). The criteria for accuracy of intraocular lens power calculations were the mean calculation error and modulus of the mean calculation error.
RESULTS: The mean calculation errors were 0.00±0.39 D (control), 0.12±0.50 D (group 2), and 0.26±0.59 D (group 3) (p=0.003), indicating a hyperopic shift in groups 2 and 3. The moduli of the mean calculation error were 0.32±0.30, 0.37±0.28, and 0.52±0.45 D, respectively (p <0.001), suggesting lower predictability of refractive outcomes of phacoemulsification in patients with zonular instability.
CONCLUSION: Patients with zonular weakness showed a hyperopic shift caused by a deeper lens position after surgery. To achieve optimal refractive outcomes in this population, A-constant for an intraocular lens should be further optimized.
Full Text

About the authors
Dmitrii F. Belov
City Multifield Hospital No. 2; Saint Petersburg State University
Email: belovd1990@gmail.com
ORCID iD: 0000-0003-0776-4065
SPIN-code: 2380-2273
MD, Cand. Sci. (Medicine)
Russian Federation, Saint Petersburg; Saint PetersburgVitaly V. Potemkin
City Multifield Hospital No. 2; Academican I.P. Pavlov First St. Petersburg State Medical University
Author for correspondence.
Email: potem@inbox.ru
ORCID iD: 0000-0001-7807-9036
SPIN-code: 3132-9163
MD, Dr. Sci. (Medicine)
Russian Federation, Saint Petersburg; Saint PetersburgVadim P. Nikolaenko
City Multifield Hospital No. 2; Saint Petersburg State University
Email: dr.Nikolaenko@mail.ru
ORCID iD: 0000-0002-6393-1289
SPIN-code: 4906-2542
MD, Dr. Sci. (Medicine)
Russian Federation, Saint Petersburg; Saint PetersburgBernora O. Ruziboeva
Saint Petersburg State University
Email: st072295@student.spbu.ru
ORCID iD: 0009-0007-1180-6631
Russian Federation, Saint Petersburg
References
- Melles RB, Holladay JT, Chang WJ. Accuracy of intraocular lens calculation formulas. Ophthalmology. 2018;125(2):169–178. doi: 10.1016/j.ophtha.2017.08.027
- Belov DF, Danilenko EV, Nikolaenko VP, Potemkin VV. Evaluation of the accuracy of modern intraocular lens calculation formulas when optical biometry is not possible. Russian Annals of Ophthalmology. 2024;140(2):34–39. doi: 10.17116/oftalma202414002134 EDN: SJKQYV
- Chen Y-A, Hirnschall N, Findl O. Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer. J Cataract Refract Surg. 2011;37(3):513–517. doi: 10.1016/j.jcrs.2010.10.041
- Hoffer KJ. Accuracy of ultrasound intraocular lens calculation. Arch Ophthalmol. 1981;99(10):1819–1823. doi: 10.1001/archopht.1981.03930020693014
- Jin H, Holzer MP, Rabsilber T, et al. Intraocular lens power calculation after laser refractive surgery: corrective algorithm for corneal power estimation. J Cataract Refract Surg. 2010;36(1):87–96. doi: 10.1016/j.jcrs.2009.07.011
- Erickson P. Effects of intraocular lens position errors on postoperative refractive error. J Cataract Refract Surg. 1990;16(3):305–311. doi: 10.1016/s0886-3350(13)80699-2
- Potyomkin VV, Ageeva EV. Zonular instability in patients with pseudoexfoliative syndrome: the analysis of 1000 consecutive phacoemulsifications. Ophthalmology Reports. 2018;11(1):41–46. doi: 10.17816/OV11141-46 EDN: YVLXBA
- Hoffer KJ, Savini G. Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials. Ophthalmology. 2021;128(11):115–120. doi: 10.1016/j.ophtha.2020.07.005
- Müller M, Pawlowicz K, Böhm M, et al. Impact of pseudoexfoliative syndrome on effective lens position, anterior chamber depth changes, and visual outcome after cataract surgery. Clin Ophthalmol. 2021;15:2867–2873. doi: 10.2147/OPTH.S307487
- Gür Güngör S, Akman A, Asena L, et al. Changes in anterior chamber depth after phacoemulsification in pseudoexfoliative eyes and their effect on accuracy of intraocular lens power calculation. Turk J Ophthalmol. 2016;46(6):255–258. doi: 10.4274/tjo.56659
- Vokrojová M, Havlíčková L, Brožková M, Hlinomazová Z. Effect of capsular tension ring implantation on postoperative rotational stability of a toric intraocular lens. J Refract Surg. 2020;36(3):186–192. doi: 10.3928/1081597X-20200120-01
- Kulikov AN, Danilenko EV, Dzilikhov AA. Assessment of the capsular tension ring implantation effect on the IOL position in the long term period after uncomplicated phacoemulsification. Ophthalmology in Russia. 2021;18(4):827–832. doi: 10.18008/1816-5095-2021-4-827-832 EDN: LFRIVQ
- Weber M, Hirnschall N, Rigal K, Findl O. Effect of a capsular tension ring on axial intraocular lens position. J Cataract Refract Surg. 2015;41(1):122–125. doi: 10.1016/j.jcrs.2014.04.035
- Belov DF, Nikolaenko VP. Effect of capsular tension ring implantation during phacoemulsification on postoperative refraction. Ophthalmology in Russia. 2022;19(3):489–492. doi: 10.18008/1816-5095-2022-3-489-492 EDN: BXSRKP
- Belov D, Nikolaenko V, Potemkin V. Effect of capsular tension ring implantation during phacoemulsification on postoperative refraction. Eur J Ophthalmol. 2022;32(4):2189–2193. doi: 10.1177/11206721211051920
- Belov DF, Nikolaenko VP. The influence of concomitant glaucoma on IOL power calculation accuracy. Ophthalmology Reports. 2020;13(1):5–9. doi: 10.17816/OV19025 EDN: OZOELI
- Belov DF, Nikolaenko VP. Alternative method of intraocular lens power calculation in eyes with short axial length. Russian Annals of Ophthalmology. 2022;138(3):24–28. doi: 10.17116/oftalma202213803124 EDN: WSWRBP
- Belov DF, Potemkin VV, Nikolaenko VP. Optimization of intraocular lens power calculation in pseudoexfoliation syndrome. Russian Annals of Ophthalmology. 2021;137(4):38–42. doi: 10.17116/oftalma202113704138 EDN: XMEDXT
- Chen H, Lin H, Lin Z, et al. Distribution of axial length, anterior chamber depth, and corneal curvature in an aged population in South China. BMC Ophthalmol. 2016;16(1):47. doi: 10.1186/s12886-016-0221-5
- Potyomkin VV, Goltsman EV. Cataract surgery in pseudoexfoliation syndrome. Ophthalmology Reports. 2020;13(1):37–42. doi: 10.17816/OV25739 EDN: DQZPOW
- Abulafia A, Barrett GD, Koch DD, et al. Protocols for studies of intraocular lens formula accuracy. Am J Ophthalmol. 2016;164:149–150. doi: 10.1016/j.ajo.2016.01.010
- Sanders D, Retzlaff J, Kraff M, et al. Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas. J Am Intraocul Implant Soc. 1981;7(4):337–340. doi: 10.1016/s0146-2776(81)80031-6
Supplementary files