Examination of the contamination aetiological agent of legionellosis in the water supply systems of medical treatment facilities


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

This study considers the features of colonization of water distribution systems by Legionella in large multi-type health-care facilities in Moscow-city, Russia. The investigation of 16 pavilions in 5 multi-type health-care facilities had found the hith level of hot water systems contaminated by Legionella pneumophila (68%), including the risk units. Among the different species of Legionella pneumophila, circulating in hot water systems of health-care facilities, the following strains had prevailed: the serogroup 6 (44%), 5 (26%) and 1 (13%). The findings conclude that certain prevention measures should be taken for microbial control and ensuring water safety in water systems of health-care facilities to prevent the nosocomial cases of legionellosis.

Full Text

Restricted Access

References

  1. Аляпкина Ю.С., Дронина Ю.Е., Карпова Т.И. и др. Применение ПЦР в реальном времени для выявления легионелл в объектах окружающей среды // Журн. микробиол. - 2009. - № 2. - С. 75-80.
  2. Белевитин А.Б., Акимкин В.Г., Мосягин В.Д. и др. Организационно-эпидемиологические аспекты профилактики внебольничной пневмонии в воинских коллективах // Воен.-мед. журн. - 2009. - Т. 330, № 9. - С. 56-63.
  3. Дронина Ю.Е., Тартаковский И.С., Люк К. и др. Моноклональные антитела к липополисахариду легионелл и их значение для типирования возбудителя // Жизнь без опасности. - 2010. - № 4. - С. 122-125.
  4. Егорова Н.А., Букшук А.А., Красовский Г.Н. Актуальные аспекты горячего водоснабжения населения // Гиг. и сан. - 2009. - № 2. - С. 91-93. «<Военно-медицинский журнал», 5’2012
  5. Карпова Т.И., Дронина Ю.Е., Тартаковский И.С. и др. Природные биопленки легионелл и их роль в эпидемиологии инфекции: методы изучения и моделирования // Журн. микробиол. — 2008. — № 2. — С. 13—16.
  6. Садретдинова О.В., Груздева О.А., Карпова Т.И. и др. Контаминация Legionella pneumophila систем горячего водоснабжения зданий общественного назначения, в том числе лечебно-профилактических учреждений // Клин. микробиол. и антимикроб. химиотер. - 2011. - № 2. - С. 163-167.
  7. Тартаковский И.С., Гинцбург А.Л., Лазикова Г.Ф. и др. Стандарты лабораторной диагностики легионеллеза и их применение во время эпидемической вспышки пневмоний в г. Верхняя Пышма // Журн. микробиол. - 2008. - № 2. - С. 16-19.
  8. Тартаковский И.С., Синопальников А.И., Дёмина Ю.В., Груздева О.А. Профилактика легионеллеза как основа для нового направления профилактики нозокомиальных инфекций // Клин. микробиол. и антимикроб. химио-терап. - 2010. - Т. 12, № 4. - С. 272-283.
  9. Темежникова Н.Д., Синопальников А.И. Болезнь легионеров: клинические аспекты осложнений, лечения и прогноза // Воен.-мед. журн. - 2008. - Т. 329, № 2. - С. 54-58.
  10. Темежникова Н.Д., Тартаковский И.С. Легионеллезная инфекция.- М.: Медицина, 2007.
  11. Шкарин В.В., Благонравова А.С., Чубукова О.А. и др. Контаминация объектов внешней среды ЛПУ бактериями Legionella pneumophila // Журн. микробиол., эпидемиол. и иммунол. - 2011. - № 2. - С. 75-78.
  12. Borellia P., Montagna M., Romano-Spica V. et al. Legionella infection risk from domestic hot water // Emerg. Infect. Dis. - 2004. - Vol. 10. -P. 457-464.
  13. France Government Guidelines. Relative to the prevention of Risks Linked to Legionella in Health Establishements: DGS/SD7A/SD5C/E4. - N 2002/243 of 22/04/02 Guidelines. - Paris, 2002.
  14. Guidelines for preventing health-care associated pneumonia 2003: recommendation of CDC and the Health care Infection Control. Practices Advisory Committee // MMWR Recomm.Rep. - 2004. - Vol. 26 (RR-3). - P. 1-36.
  15. Guidelines for drinking-water quality. -Geneva: WHO, 2004.
  16. Legionella and the prevention of legionellosis. - Geneva: WHO, 2007. - 252 p.
  17. Pedro-Botet M.L, Sopena N., Garcia-Cruz A et al. Streptococcus pneumophilia pneumonia in HIV-infected patients // Scand. J. Infect. Dis. - 2007. - Vol. 39, N 2. - P. 122-128.
  18. Rogues A., Boulestreau H., Lasheras C. et al. Contribution of tap water to patient colonization with Pseudomonas aeruginosa in a medical intensive care unit // J. Hosp. Infection. - 2007. -Vol. 67. - P. 72-78.
  19. Sabria M., Campins M. Legionnaires Disease: update on epidemiology and management options // Am. J. Respir. Med. - 2003. - Vol. 2(3). - P. 235-243.
  20. Sabria M., Pedro-Botet M., Gomez J. et al. Environmental cultures and hospital-acquired Legionnaires’ disease: a 5-year prospective study in 20 hospitals in Catalonia, Spain // Jnfect. Contol. Hosp. Epidemiol. - 2004. - Vol. 25. - P. 1072-1076.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2012 Gruzdeva O.A., Tartakovsky I.S., Maryin G.G.



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: № 01975 от 30.12.1992.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies