Results of Cementless Femoral Components Use at Revision Hip Arthroplasty

Cover Page


Cite item

Full Text

Abstract

Results of 98 revision total hip arthroplasties performed using cementless stems during the period from 2000 to 2012 are presented. In 1 st group of patients (36 operations) revision SLR stems were used. In group 2 (34 interventions) and group 3 (28 interventions) Solution stems and Wagner stems were implanted, respectively. Detailed characteristic of implants was given with account to the type of fixation. Follow up was from 3 to 6 years. Excellent and good results were achieved in 21 patients (58.33%)from the 1 st group, 14patients (41.18%) from the 2 nd group and 16 patients (57.14%) from the 3 rd group. Analysis of intraoperative, early (up to 6 months) and late (over 6 months) complications was performed. Recommendations for choice of revision femoral components depending on the degree of bone tissue defect are given.

Full Text

Результаты применения бедренных компонентов бесцементной фиксации при ревизионном эндопротезировании тазобедренного сустава
×

References

  1. Dohmae Y., Bechtold J.E., Sherman R.E., Puno R.M., Gustilo R.B. Reduction in cement-bone interface shear strength between primary and revision arthroplasty. Clin. Orthop. Relat. Res. 1988; (236): 214-20.
  2. Загородний Н.В. Эндопротезирование тазобедренного сустава. Основы и практика: руководство. М.: ГЭО- ТАР-Медиа; 2011.
  3. Bьhler D., Berlemann U., Lippuner K., Jaeger P., Nolte L. Three-dimensional primary stability of cementless femoral stems. Clin. Biomech. (Bristol, Avon). 1997; 12: 75-86.
  4. Загородний Н.В., Нуждин В.И., Бухтин К.М., Кагра- манов С.В. Результаты применения бедренных компонентов цементной фиксации при ревизионном эндопротезировании тазобедренного сустава. Вестн. травматол. ортопед. 2012; 3: 32-8.
  5. Greidanus N.V., Antonious J., Paprosky W.G. Extensively œated cementless femoral components in revision hip arthroplasty. Surgical Technology International IX. May 2000: 267-72.
  6. Paprosky W.G., Greidanus N.V., Antoniou J. Minimum 10-year results of extensively porous-coated stems in revision hip arthroplasty. Clin. Orthop. Relat. Res. 1999; (369): 230-42.
  7. Meek R.M., Garbuz D.S., Masri B.A., Greidanus N.V., Duncan C.P. Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J. Bone Jt Surg. Am. 2004; 86 (3): 480-5.
  8. Moreland J.R., Bernstein M.L. Femoral revision hip arthroplasty with uncemented, porous- coated stems. Clin Orthop. 1995; (318): 141-50.
  9. Nadaud M.C. , Griffin W.L., Fehring T.K., Mason J.B., Tabor O.B. Jr, Odum S., Nussman D.S. Cementless revision total hip arthroplasty without allograft in severe proximal femoral defects. J. Arthroplasty. 2005; 20 (6): 738-44

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2012 Eco-Vector



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77-76249 от 19.07.2019.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies