Efficacy of Robotic Assistance Method for Stabilization of Lumbar-Sacral Spine

Abstract

First experience in performance of spinal segments' stabilization using robotic assistance (SpineAssist, MAZOR Surgical Technologies, Caesarea, Israel) in Russia is presented. Between August 2009 and August 2010 twenty six surgical interventions using that technique were performed at Spinal Department of RAMS Institute of Neurosurgery named after N.N. Burdenko. Preoperative neuro-visualization included spondylography, MRI, CT with sections <1 mm that was essential for preoperative planning using computed work station SpineAssist. The robot was used for automated navigation of instruments in operative wound according to preoperatively planned path. New system of transcorporal stabilization of spinal segments Go-Lif required only two screws for fixation was compatible with fusion technique and was of special interest. Robotic assistance enabled to obtain optimum location of implants in all cases even in presence of anatomical peculiarities of the operated segments (thin vertebral arch roots, rotative deformity of vertebrae. Basing on the results of control CT examination and comparison of obtained CT data with preoperative planning data it was shown that with robotic assistance clinical accuracy of implant location was within 1 mm). No complications related to implant insertion were observed.

References

  1. Berlemann U., Monin D., Arm E. et al. Planning and insertion of pedicle screws with computer assistance //J. Spinal Disord. - 1997. - Vol. 10. - P. 117-124.
  2. Brantigan J.W., Neidre A., Toohey J.S. The lumbar I/F cage for posterior lumbar interbody fusion with the variable screw placement system: 10-year results of a Food and Drug Administration clinical trial //Spine J. - 2004. - N 4. - P. 681-688.
  3. Esses S.I., Sachs B.L., Dreyzin V. Complications associated with the technique of pedicle screw fixation: a selected survey of ABS members //Spine. - 1993. - Vol. 18. - P. 2231-2238.
  4. Gaines R.W. Jr. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders //J. Bone Jt Surg. - 2000. - Vol. 82A. - P. 1458-1476.
  5. Gertzbein S.D., Robbins S.E. Accuracy of pedicular screw placement in vivo //Spine. - 1990. - Vol. 15. - P. 11-14.
  6. Jerosch J., Malms J., Castro W.H. et al. Accuracy of pedicle screws following instrumented dorsal fusion of the lumbar spine //Z. Orthop. Ihre Grenzgeb. - 1992. - Bd 130. - S. 479-483.
  7. Lieberman I..H., Togawa Ph.D., Kayanja M. et al. Bone-mounted miniature robotic guidance for pedicle screwand translaminar facet screw placement: Part I - Technical development and a test case result //Neurosurgery. - 2006. - Vol. 59. - P. 641-650.
  8. Nazarenko A.G. Multicriterian assessment of the degenerative lumbar spine diseases //Materials of 14 World Congress of neurological surgery. - Boston, 2009. - P. 55.
  9. Nazarenko A.G. Outcome prognosis for the patients with degenerative lumbar spine diseases //Materials of 14 World Congress of neurological surgery. - Boston, 2009. - P. 54.
  10. Nolte L., Zamorano L., Arm E. et al. Image-guided computer-assisted spine surgery: a pilot study on pedicle screw fixation //Stereotact Funct. Neurosurg. - 1996. - Vol. 66. - P. 108-117.
  11. Nolte L.P., Zamorano L.J., Jiang Z. et al. Image-guided insertion of transpedicular screws: a laboratory set-up //Spine. - 1995. - Vol. 20. - P. 497-500.
  12. Slomczykowski M., Roberto M., Schneeberger P. et al. Radiation dose for pedicle screw insertion: fluoroscopic method versus computer-assisted surgery //Spine. - 1999. - Vol. 24. - P. 975-982.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2010 Eco-Vector



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77-76249 от 19.07.2019.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies